06/15 Rev. 6.00-02 USER- / SERVICE MANUAL Info-Printouts & Parameters64-xx – DPM – PEM – ALX 92x – ALX 73x (PMA)109OLV PARAMETERS This menu only appears, if an online verifier (OLV) is connected to theprinter. For this, the parameter INTERFACE PARA > COM2 PORT > Function Option mustbe set to „Barcode OLV“.Verify mode64-xx ALX 92x DPM PEM Only if OLV PARAMETER > Cancel. printing = „On“.All bar codes All bar codes are being checked according to the limits set at the printer. Easy-Plug print jobs don´t have to be modified when using this setting.Easyplug select. Only those bar codes are being verified, which have the „V“ set in the com-mand option. For details refer to the Easy-Plug manual, command #YB.Cancel. printing64-xx ALX 92x DPM PEM 64-xx: Parameter is not supported for dispenser version.Cancellation printingOff No cancellation printing.On If no validation data for the printed bar code was sent, or if the bar code ex-ceeds the set limits, the faulty printed label is cancelled. Afterwards, the samelabel is reprinted. The amount of reprints can be set with the parameter „Re-print quantity“. If the error still occurs after the so defined quantity of labelswas reprinted, the printing stops and an adequate error message appears.Reprint quantity64-xx ALX 92x DPM PEM Only, if OLV PARAMETER > Cancel. printing = „On“.Defines the maximum amount of reprint attempts after a bar code read error.xxx Setting range: 0 to 10, Unit interval: 1; Default setting: 0OLV mode64-xx ALX 92x DPM PEMFast legacy No additional material feed is made, if the bar code is near the end of a label.An additional material feed is only made if the last label of a job is printed andthe printer has to stop. This is the behaviour of a Gen. 1 printer with firmware3.40.Limitations:• OLV PARAMETERS > Cancel. printing is not available