9-108P0351EAS20580P0351EAS33060TROUBLESHOOTINGItemIgnition coil: open or short circuit detected in the primary lead of the ignition coil.Fail-safe system• Unable to start engine• Unable to drive vehicleProcedure1. Connection of ignition coil coupler.• Check the locking condition of the coupler.• Disconnect the coupler and check the pins (bent or broken terminals and locking condition of thepins).2. Connection of ECU coupler.• Check the locking condition of the coupler.• Disconnect the coupler and check the pins (bent or broken terminals and locking condition of thepins).3. Wire harness continuity.• Disconnect the ignition coil coupler and ECU coupler.• Open circuit checkIs the coupler condition normal?YES Go to step 2.NOa. Connect the coupler securely or replace the wire harness.b. Start the engine and let it idle for approximately 5 seconds.c. Check the condition of the DTC using the malfunction mode of the YDT.Is it in the “Recovered” condition?YES Go to step 7, and complete the service.NO Go to step 2.Is the coupler condition normal?YES Go to step 3.NOa. Connect the coupler securely or replace the wire harness.b. Start the engine and let it idle for approximately 5 seconds.c. Check the condition of the DTC using the malfunction mode of the YDT.Is it in the “Recovered” condition?YES Go to step 7, and complete the service.NO Go to step 3.Between ignition coil coupler “1” and ECU cou-pler “2” orange–orange