Installation Azbil Corporation2-4 Model MGG10C/14C - MagneW FLEX+/PLUS+ ConverterFigure 2-3 Pipe mounted remote installationChanging the orientation of the converterThe model selected when the flowmeter is purchased determines the orientation of thedisplay. It is possible, however, to change the horizontal or vertical orientation of theconverter.To change the orientation of the converter:1. Remove the four screws holding the display cover to the main body and removethe cover.2. Remove the four screws holding the display panel to the main body.3. Remove and rotate the display panel to the required orientation.4. Replace the four screws and tighten.5. Rotate the display cover so that the openings for the LEDs are correctly alignedwith the Display Panel.6. Replace the four screws and tighten.