Using the display panel Azbil Corporation4-44 Model MGG10C/14C - MagneW FLEX+/PLUS+ ConverterSetting / Changing the preset value of the built-in flow counterThis changes the contact output status from H to L or from L to H when the flowcounter reaches a preset value.This function is used when contact output has been selected.Also, be sure to select the preset counter for the contact output in function setting.(See page 4-25)Default settingThe preset value is set to “0000000000” at shipment.Setting range0000000000 - 9999999999Step Screen Procedure(English) (Japanese)1 COUNTER PRESET0000200000 0000200000Open the built-in flow counterpreset value setup screen byfollowing the steps to enter theEngineering mode.2 COUNTER PRESET0000200000 0000200000Touch the key to move thecursor to the desired digits.In this example, the cursor ismoved to the “2” position bytouching the RIGHT SHIFT keyfive times.3 COUNTER PRESET0000500000 0000500000Touch the or key to set thedesired numbers.In this case, the numeral “2” ischanged to “5” by three touchesof the increment key.4 COUNTER PRESET0000500000 0000500000When the counter reset valuehas been changed, touch thekey to return the cursor to the“#”.