116Setting CheckersChapter 66.9.3 Setting ProcedureInspection Conditions1. Proceed up to “Configure the setting for preprocessing” at the third step following section 6.2.1.2. Select “Detection Object”.Choose “Normal” or “Low Contrast”.If you set the Smart Matching checker first, precede to the next step while “Normal” (initial value) isselected.The Low Contrast function is effective if the contrast between the object image and the background is verylow or the some parts of the image of the object may disappear, chipped or shielded, or for the noises inthe uneven background. But, the image processing time in the mode will be longer than in normal mode.Refer to page 119 for settings of a low contrast image.3. Select "Template".4. Select "Change".5. Set the area you want to save as a base image and decide the startand end points.Set a mask area as necessary.6. Move the output point (the currently displayed "+" mark) and press the ENTER key.You can position the output point outside the template area. Even if theoutput point is placed out of the display area its detection position can beoutput. When the template area is displayed in yellow, the templatesetting is completed.Output point Output point is the one that indicates the location of an image when the same image as thetemplate was detected. After image detection, the coordinate values of this point are outputto the external device. You can place the output point at the desired location (the outputpoint does not always have to be positioned within the template area.).Setting the outputpoint as a "middlepoint".1. Press the B key in the state that the output point can be positioned.2. When appears, press the ENTER key. The output point movesto the center of the template area.3. Press the ENTER key to fix the position. When the output point disappears andthe template area appears in green, the template area setting has beensuccessfully completed.• The following messages may be displayed when setting a template.E0130 Image has no features.This message indicates the image in the template area has no or a few features. Check the grayscaleimage. If you still cannot save the template after doing so, adjust the size of the template area.• The template can be updated (or re-registered using the current image) by using the input signals fromthe external device. See section 10.5.3 for details.