34Input and Output Interface PortsChapter 3Flash Output TerminalsDo not commonly use COMMON for FLASH with other COMMON terminals.Output Circuit: Product number with final number “N”Rated operating voltage: 5 to 24 V DCrated operational voltage: 5 to 24 V DCOutput Circuit: Product number with final number “P”Rated operating voltage: 5 to 24 V DCrated operational voltage: 5 to 24 V DCFlash Timing ChartNote that the time from the FLASH output signal ON to the emission completion (including the times listed below)does not exceed 420 μs.• Flash output sync. Signal lag of PV310. This signal lag changes depending on the attached strobe.• Strobe response time. The time differs depending on the used strobe.• Strobe flash time. The time differs depending on the used strobe.• Set the shutter speed of a double speed random camera within the range from 1/30 to 1/1000 whenusing a strobe light.• You cannot use the same strobe light to the cameras connected to each PV310.• When a strobe is used, the strobe lights flash continuously during Live-image display. When makingsettings and performing inspection by using a strobe light, switch to memory image display.