266RS-232C Communication Chapter 11Re-registering the template - Area Display: YesTo complete re-registering the template, this command must be sent from external device to PV310 twice.Communication direction Command / DescriptionFrom the External Device toPV310 (1st. time) % A ? ? CR??: 01 to 99 (Specify the number of the folders where product types andconfiguration data are stored in 2-digit form.)Response (1st time)-Normal (at the end ofre-registering the template)% A CRFrom external device to PV310(2nd. time) % A CRResponse (2nd. time): Normal(at the end of re-registering thetemplate)% A CRResponse: Error 1 % U CRCause:Command in the unspecified form or not provided was received.Examples:- %F CR (any other checker number than 01 - 99 was specified. (1- or morethan 3-digit numbers were specified.))- %B01 CR (not provided command)Response: Error 2• ERROR signal = “ON”• Error Code: E0174 isdisplayed on the screen% Z CRCauses:• The checker types already saved as the specified numbers are not SmartMatching or Contour Matching.• Template is not registered using the Smart Matching or Contour Matchingchecker already saved as the specified number.• As the image in the re-registration area has no feature, it cannot be registeredas a template.• When re-registration position = Adjusted Position, grouped Position Adjustment(or Rotation Adjustment) is NG• When re-registration position = Adjusted Position, the position adjusted usinggrouped Position Adjustment (or Rotation Adjustment) checker is out of thescreen.Processing flow• When a live image is displayed, it is newly re-registered after being captured.• When a memory image is displayed, template is registered using the currently displayed memory image(the last captured image).• The images are discarded when the power turns off unless saving them. To hold the images even if thepower turns off, save the current settings by selecting "SAVE" from the menu bar or by inputting acommand of "%MCR" from the external device.