222Environment Settings Chapter 99.2 Initial Settings9.2.1 List of Initialization Menu OptionsItem Option DetailsD.S. Random FrameD.S. Random FieldSelect when using a double-speed random camera(ANM831).Normal FrameNormal FieldSelect when using a standard camera (ANM832) or an ultracompact camera (ANPVCA1012).Int. Sync Mode FrameCamera ModeInt. Sync Mode FieldSelect when using NTSC input signal.1/120, 1/200,1/500,1/1000, 1/2000, 1/4000,1/8000 and 1/20000s (forD.S.Random Frame/Field)Shutter Speed1/30, 1/125, 1/500, 1/1000,1/2000, 1/4000, 1/10000s(for Normal Field or Int.Sync Mode Field)When setting Camera mode to D.S. Random Frame/Field,Normal Field or Int. Sync Mode Field mode, you can setshutter speed.When using an ultra compact camera, this setting is invalid.Change the shutter speed by using the dedicated cameracontrol unit.Shutter speed is fixed to 1/30s in other modes.Once To start inspection using input signals from the externaldevice.StartRepeat To start an inspection after being activated and beforereceiving input signals from the external device and inspectrepeatedly.Password Up to eight digits Required for switching from RUN to SETUP mode.Yes Password is requested when switching from RUN mode toSETUP mode.Password RequestNo Password is not requested when switching from RUN toSETUP mode.Background(at Startup)Translucent/ Solid Select a background color of the menu window. (But, thesetting of Background is invalid until the PV310 is turned onnext time.)If you set it to “Translucent”, you can recognizean image or checker shape displayed in the position of themenu window.Language English/ Japanese* To change a display language.