124Setting CheckersChapter 6Checking the ResultsYou can view the test results obtained by executing Smart Matching checker under the Result tab.1. Highlight the Result tab.2. Press the A key and begin a test.Up to eight x/y coordinates and differential values of the objects from the 1st to 64th can be viewed perscreen. The image area of the highlighted object number is displayed in red, so that you can easily checkthe data on the monitor screen.When you check the data after (or before) the 9th, choose the 8th number and tilt the ENTER keydownward (or choose the 1st number and tilt the ENTER key upward).Max. Subtraction:In the Max. Subtraction column, the area value ofthe biggest cluster among the detected pixelclusters is displayed.Correlation Value:The correlation value detected at the last phase ofthe sequence. But, if you set “Object” to “LowContrast”, the value different from the correlationvalue of the part detected at the last phase of thesequence is displayed. Refer to page 120.• Up to 128 subtraction clusters can be detected. If the number of subtractions exceeds 128, the result ofsubtraction will automatically be 255 due to occurrence of subtraction count error.• If you test on a checker menu, the operation of the PV310 differs depending on the currently displayedimage.Display Image Operation of PV310Live Tests after capturing a new imageMemory Tests using a memory image that is currently displayed withoutcapturing a new image