317Chapter 15 TroubleshootingCause RelevantFunctionErrorCode Check and ResponseCamera capturing error• Connects a normal camera: ANM832 and sets D.S.RandomFrame/Field mode.• The DIP switch setting of a D.S. Random camera does notcorrespond with the camera mode selected with PV310.E.g.)Camera mode: D.S. Random FrameDIP switch setting: Field (No.6 = OFF)• Connects a D.S. Random camera to Camera port B.• Connects a D.S. Random camera with a camera cableincorrectly or a cable disconnected.E0071 Connect and set correctly. If the errorreoccurs, try the following procedures.• Cut the power and reconnect thecamera cable.• Replace the cable.Problem: ERROR (error) signal is output while inspection is not performed.Timing ErrorCode CauseWhen data saving E0170 When PV310 failed to save data by serial command inputand returned error response “%Z” to the external device.When product types were switched E0171 Product types were switched by specifying the number ofthe product type that has not been created.When display images were switched E0172When the data of CF card was restored. E0173When a template was re-registered E0174By using parallel (I/O) signalExecution signal (FCT1/FCT2) was input by specifying anundefined combination of IN1-IN3 or IN1 –IN7 signals.By using serial commandWhen each command was input, the PV310 returned errorresponse “%Z” to the external device.When changing the binary slice level E0175When referring Gray Edge threshold value E0176When changing Gray Edge thresholdvalueE0177When referring numerical calculationmaximum/minimum valueE0178When changing numerical calculationmaximum/minimum valueE0179When serial command was input, the PV310 returned errorresponse “%Z” to the external device.For more information, refer to Chapter 11.2.6 “Details ofCommands”.During AXTOOL communication E0180 More than 30 seconds has passed since communication thePV310 and external device was disconnected by removingthe Ethernet cable while the PV310 was communicating withAXTOOL. Ver. 3.