117Setting CheckersChapter 67. Select "Search Area".Follow the steps used for area setting (the Search Area function is set to full screen by default).8. Select "Position Adj." and press the ENTER key.(If a position adjustment checker is not created, the option “PositionAdj.” is deactivated.)When making a position/rotation adjustment, specify the number ofPosition Adjustment checker from the submenu. (See 140 for PositionAdjustment and 152 for Rotation Adjustment.)9. Set "Angle Range".Select an angle range for searching. Angle range from 0 to 180 isavailable. If you set the angle range to “180”, the PV310 can searchwithin the limit of +/-180 (360).Note that the larger the setting value of rotation angle range, the longerinspection time.10. Select “Angle Search”.Before searching the rotation direction of the object, the angle (the level of search angle) at which you wantto let the PV310 search the rotation direction of the object for each inspection. If you set to “Normal”, thePV310 searches while tilting the template by 4-degree angle and re-search around the detected angle at alow angle.Setting Angle Processing time Detection accuracyRough 8Normal 4Fine 2FastSlowLowHigh11. Set "Rot. Accuracy".Set the minimum unit of detected angle.Setting Detected angle1 degree 45 degreeExample of settings and detected angle0.1 degree 45.3 degree12. Select "Sorting".The submenu is displayed.SortingThe Sorting function is necessary for usingthe feature data of the object ((forCalculation, Statistics and Data Monitorwindows). With this function, when multipleimages were detected, they are arrangedin descending or ascending order based oncorrelation, and X- /Y-coordinate. You canspecify the number of the object by alwaysarranging multiple objects in certain order.