268RS-232C Communication Chapter 11Changing Max. /Min. Slice Level ([%T])This is a command to change Max. /Min. Slice Level by specifying a binary label group A - H. The max/min. slicelevel of the currently selected product type can be changed.Command format: Comma separatedCommunication Direction Command / DescriptionFrom external device to PV310 % T ? ? , a a a , b b b CR?? : 01 to 08 (Specify the number of Slice Level in 2-digit form)Slice Level A B C D E F G HSpecified number 01 02 03 04 05 06 07 08aaa : 000 to 254 or 0 to 254 (Slice level-min.: 1 to 3 digits)bbb : 001 to 255 or 1 to 255 (Slice level-max. 1 to 3 digits)For example, if slice level =1, Min.=20 and Max.=255, the command is %T01, 20,255 CR or %T01, 020, 255 CRResponse: At Normal % T ? ? , a a a , b b b CRThe same command as the sending command from external device to PV310 istransmitted.Response: Error 1 % U CRCause:Command in the unspecified form or not provided was received.Examples:- %T1,80,255 CR (any other checker number than 01 - 08 was specified)- %B01 CR (not provided command)Response: Error 2• ERROR signal = “ON”• Error Code: E0175 isdisplayed on the screen% Z CRCauses:• The max. value of Slice Level specified by a sending command is smaller thanthe min. value of Slice Level.• The max. value of Slice Level is equal to the min. value of Slice Level.• Max./min. values of Slice Level specified by sending command are not withinthe range between 000 or 0 and 255.To specify the command format (Comma separated/Fixed Length), select “ENVIRONMENT” > “SerialCommunication” > “Command” from the menu bar.