32Input and Output Interface PortsChapter 33.1.5 Output TerminalsArrangement of the terminalsSignal Name ContentCOM COMMON For FLASH onlyFLA FLASH Flash sync signalCOM COMMON Common terminal for General OutputRDY READY Ready signalERR ERROR Error signal (refer to page 316 formore details of error causes.)REN READ END Image capture completion signalSTR STROB Strobe signal (Data output completionsignal during handshake )OVF OVER FLOWFLAGOverflow signal (this signal is output ifthe output value exceeds the datalength you have set)D1 DataD2 Data2D3 Data3D4 Data4D5 Data5D6 Data6D7 Data7D8 Data8Data output signals• Number of scans• Data of Judgment• Data of Numeric Calculation• Data of StatisticsOutput Circuit:Product number with final number “N”The NPN open collector output is adopted. The load current should be within the rated voltage range.Rated operating voltage: 12 to 24 V DC A connecting example with PLC