56Procedure for Setting Inspection ConditionsChapter 55.1 Setting Inspection ConditionsSet the inspection conditions in the following order. The details of each step are described in the next page orlater.1 Select a camera mode. Select a type or mode of the connected camera, or ifnecessary, select shutter speed.Sections5.2 and 5.3Camera mode and shutter speed is common to all producttypes.2 Select a product type No. Select the number of a product type in which a combination ofinspection conditions is stored. Section 5.4Available product type numbers: 1 – 642-a If you want to execute some of the checkers in theproduct type, set the PV310 to SETUP mode. Section 7.23 Capture the image of theinspection object.Put the inspection object under the camera lens and capturethe image into the memory. Section 5.54 Set a checker. Set a inspection area and conditions Section 64-aIf you let the PV310 compute using each detectedvalue, use the Numeric Calculation function.If you output each detected value to the externaldevice, save the data as Numeric Calculation dataand output it.Section 7.25Configure the settings foroutputting judgment result tothe external device.Configure the settings for outputting inspection judgmentresult OK or NG to the external device. Section 7.1.25-aIf you output thesettings dataconfigured at thestep 4-a, set theway of outputtingthe settings data oroutput format.Refer to page 219 for setting outputdestination.For parallel communication: Section 10For serial communication: Section 11For Ethernet communication: Section 12For Compact flash memory card: Section13.56 Display the inspection result. Display Judgment result (OK or NG) in the total Judgmentresult display area. Section 07 Save the setting data Store the setting data in PV310. Section 5.78 Execute inspection Execute inspection by changing to RUN mode. Section 5.8