215TOOLChapter 8To check the number of the executed blockThe number of the executed block is displayed in the information area.How to set a block numberWhen you input inspection start signal, START signal or inspection start serial command from the external device,specify the desired block. The block number can be specified when inspection is executed by using the keypad, too.How to specify a block number when starting an inspection by I/O inputSpecifiedblock IN2 IN1 START1 OFF OFF ON2 OFF ON ON3 ON OFF+ONWhen you input START signal, control inspectionexecution by using I/O ports IN1 and IN2 as thetable shown on the right.Enter IN1 and IN2 1 ms and more before entering aSTART signal.How to specify a block number when starting an inspection by sending a serial commandSpecifiedblock Command1 %S1CR2 %S2CRWhen you send a serial command to the PV310from an external device, issue a special command tospecify a block number as the table shown on theright.3 %S3CRHow to specify a block number when starting an inspection by pressing the A key on the keypadWhen you press the A key in RUN mode, a dialog box from which you can select the desired block isdisplayed. Only the selected block is executed.