133Setting CheckersChapter 66.11.3 Setting Procedure1. Proceed up to “Configure the setting for preprocessing” at the third step following section 6.2.2. Select “Area”.The menu names and basic operations are the same as the ones described in the sections 4.4.3 and 0.,but the ways of drawing an inspection area and of setting a mask area are different between flaw detectionchecker and other checkers.If Area Shape = “Line”To set a start point (ST) and an end point (ED) Setting DialogSet start and end points. You can set an area in the vertical and obliquedirections as well as in the horizontal direction.To set the size of a cell (WX, WY)Set the size of a cell to calculate the average brightness of the cells.The widths in X and Y directions of a cell are defined as the figuresshown below.X YST Xcoordinateof startpointYcoordinateof startpointED Xcoordinateof endpointYcoordinateof endpointW Width ofcell XWidth ofcell YN Number ofcells0 (fixed)To set the number of cellsSet the number of cells aligned from start point to end point in an area properly as the figure shown below. Ifthe cells are fully or partly covered with other cells, the PV310 repeatedly scans the parts where the cells arecovered with other cells, resulting in increasing inspection time.For the Area Size Adjustment function, thenumber of cells in the inspection area does notdepend on its size. Therefore, specify enoughcells for executing inspection throughout even abigger area.