Chapter 4: Connecting External Equipment (Optional)363. If necessary, daisy chain the same type of composite asset sensorsto track more IT devices.a. Get a standard network patch cable that is within 2 meters.b. Connect one end of the network cable to the RJ-45 connectorlabeled "Output" on the previous composite asset sensor.c. Connect the other end of the cable to the RJ-45 connectorlabeled "Input" on the subsequent composite asset sensor.d. Repeat the above steps to connect more composite assetsensors. See Daisy-Chain Limitations of Composite AssetSensors (on page 36) for the maximum number of compositeasset sensors supported per chain.e. It is highly recommended using the cable ties to help hold theweight of all connecting cables.4. Repeat Step 2 to connect IT devices to the other composite assetsensors in the chain.Daisy-Chain Limitations of Composite Asset SensorsThere are some limitations when daisy chaining composite asset sensors"AMS-Mx-Z," where x is a number. The maximum cable length between composite asset sensors is 2meters, but the total cable length cannot exceed 10 meters. The maximum number of composite asset sensors that can be daisychained vary according to the Raritan device.Raritan devices Maximum sensors per chainEMX2-111, Up to 4 composite asset sensors