Configurable Enhanced Modular IO Subsystem (eMIOS200)MPC5606S Microcontroller Reference Manual, Rev. 7238 Freescale SemiconductorFigure 9-4. eMIOS200 block diagram11.This diagram shows a 24-channel eMIOS200. On MPC5606S, eMIOS200_0 has 16 channels (8–23) andeMIOS200_1 has 8 channels (16–23). Thus, not all channels shown are available.Real-time signalBIUCounter Buses(Time bases)IP InterfacesubmodulesallIIBInterrupt signalsSlave bus signalsGlobal signalsDMA interface signalsGlobal TimeGlobal Timeenhanced Modular Input/Output SystemClockPrescalersystem clock internal counter clock enable................Output disable control Bus[A]CH[0] EMIOSI[0]EMIOSO[0]ipp_obe_emios_ch[0]see note 1emios_flag_out[0]Notes: 1. Connection between UC[n-1] and UC[n]CH[7] EMIOSI[7]EMIOSO[7]ipp_obe_emios_ch[7]emios_flag_out[7][B][A]CH[8] EMIOSI[8]EMIOSO[8]ipp_obe_emios_ch[8]emios_flag_out[8]ch[15] EMIOSI[15]EMIOSO[15]ipp_obe_emios_ch[15]emios_flag_out[15][C][A]CH16] EMIOSI[16]EMIOSO[16]ipp_obe_emios_ch[16]emios_flag_out[16]CH[23] EMIOSI[23]EMIOSO[23]ipp_obe_emios_ch[23]emios_flag_out[23][D]Counter Buses(Time bases) ................Counter Buses(Time bases) ................necessary to implement QDEC modeBase Enable OutBase Enable InOutput DisableInput[0:3]Notes: 2: Illustration of a 28 channel eMIOS200