Installer Menu Options i-on RangePage 903. The Master User can enable or disable HUD functions for the FOB-2W-4B and727r by using the option “User Menu – System Config – Remotes – HUA Function”.There are two options available to control sounders and siren:Sounder onUnconfirm When the system is set the control unit activates the internal sounderswhen an unconfirmed alarm occurs.Confirm When the system is set the control unit does not activate the internalsounders until a confirmed alarm occurs.Note: The control unit will not allow you to select “Sounder on - Confirm” at the same timeas “Siren on - Unconfirm”.Siren onUnconfirm The control unit operates the siren for all alarms (and overrides any SirenDelay).Confirm When the system is set the control unit does not activate the siren(s) untila confirmed alarm occurs.Note: The control unit will not allow you to select “Siren on - Unconfirm” at the same timeas “Sounder on - Confirm”.Confirmation (UK Variants)Confirmation ModeIf you are installing a UK version of the control unit then the Confirmation Mode optionallows installers to program a control unit for operation under either DD243 or BS8243.There are three options:Notes:1. Confirmation works only when the Alarm Response is set to “Siren+Comms” (seepage 80).2. The Master User can enable or disable HUD functions for the FOB-2W-4B and727r by using the option “User Menu – System Config – Remotes – HUA Function”.Basic If you select this option then the control unit will activate any outputprogrammed as “Confirmed Alarm” if a second zone is activated while thesystem is in alarm. The second zone must belong to the partition that is inalarm. The installer can also select whether to allow users to reset thesystem after a zone alarm, see page 88.In addition, when Confirmation Mode = “Basic”, the Master User can enableor disable HUD functions for all FOB-2W-4Bs and 727rs by using the option“User Menu – System Config – Remotes – HUA Function”.Note: Confirmed Hold Up Alarm is not available in Basic Confirmation Mode.DD243 If you select this option then the control unit reveals sub menus required toprogram the system to conform to DD243: Siren On, Sounder On,Confirmation Time, After Entry, Entry Keypad Lock, Unconfirmed Reset,Confirmed Reset. The rest of this section describes each of these sub-menus.Note: When using Confirmation, and the system is programmed for InstallerReset after an alarm, the user cannot set the system after an alarmuntil the installer has carried out a reset.