Installer Menu Options i-on RangePage 88Yes By pressing the user can set the system if there are zones withthe Omit Allowed attribute active.No The user must go to the Omit Menu to set the system if a zone isactive.User Code RequiredUse this option to ensure that an installer or maintainer cannot gain access to program thesystem unless a user is present:Yes After the installer/maintainer enters their access code, the systemasks for a user access code before allowing access to the InstallerMenu.No The installer/maintainer can enter the Installer Menu by simplykeying in their own code.Note: If you select this value then the control unit no longercomplies with EN50131. This value complies with BS8243only if the user has given written consent.2 Way RepliesUse this option to decide whether the control unit can send status messages to the two-way remote control unit (FOB-2W-4B).2 Way Set InstantUse this option the decide how the two-way remote control unit (FOB-2W-4B) sets thesystem:Yes The partition sets instantly when the user operates the FOB-2W-4B.No The partition follows the setting mode programmed for it in“Partitions” or “Setting Options” (see page 77).Duress EnableThis option allows Master Users to create duress user types. A duress code can set andunset the system in the same way as a Normal User. However each time the code is usedthe control unit triggers a Duress output. In addition the control unit communicates Duressas appropriate, and also a set or unset event.Yes Master Users can create Duress user types.No The Duress user type is not available to assign to users.User ResetThis menu option determines under what circumstances a user or the installer can resetthe system after an alarm.Zone Alarms(Appears when System Options – Confirmation – Confirmation Mode is set to “Basic”,see page 89.)Yes The user can reset the system after an alarm triggered by a zone’salarm circuit.No The installer must reset the system after an alarm triggered by azone’s alarm circuit. See also “Remote Reset” on page 89.Note: If a user unsets the system during an alarm, but before the Alarm Abortperiod has expired, then they can reset the system (see page 100).