i-on Range Appendix IIPage 141area (P1) follow the status of other partitions use the Partitions - Full Set Link option (seebelow).To avoid false alarms make the alarm response of the common area (Partition 1) Siren +Comms and the other two Partitions Siren only.Zone ProgrammingLocation Zone Name Zone Type PartitionsFront Door 001 Front Door Final Exit P1Foyer PIR 002 Foyer PIR Entry Route P1Loading Bay Entrance 003 LB to Foyer Final Exit P2Roller shutter 004 Rshutter Normal Alarm P2Loading Bay PIR 005 LBay PIR Entry Route P2Factory PIR 006 Factory PIR Normal Alarm P2Factory Fire Door 007 Factory FD 24 Hour P2Kitchen PIR 008 Kitchen PIR Normal Alarm P1Office Fire Door 009 Office FD 24 Hour P3Office PIR 010 Office PIR Normal Alarm P3Reception PIR 011 Recpt PIR Entry Route P3Reception Entrance 012 Rcept Door Final Exit P3Partition and Other ProgrammingMenu Sub Menu OptionAdd/delete Detectors/Devices External Radio Siren (if to be fitted)Wired keypads Keypad 01 Name = OfficePartition 3Keypad 2 Name = FactoryPartition 2Keypads 3 & 4 – notfittedNAOutputs Panel Outputs 1 = Siren2 = Strobe3 & 4 = NUPartitions P1 Name = FoyerExit Mode = Final Door SetSettle Time = 10sEntry Time = 45sAlarm Response = Siren + Comms (Full)Strobe on Set = Yes (If required)Strobe on Unset = Yes (if required)P2 Name = OfficesExit Mode = TimedExit Time = 20sEntry Time = 45sAlarm Response = Siren (Local)P3 Name = FactoryExit Mode = TimedExit Time = 20sEntry Time = 45sAlarm Response = Siren (Local)Full Set Link P2 = Yes