Installer Menu Options i-on RangePage 136Downloader and the LogWhen Downloader connects to a control unit, the control unit logs the event as “RemDownload”. This indicates that Downloader successfully connected and disconnected.The control unit logs a separate event “Unn Config Change” if Downloader changes theconfiguration of the control unit. The user number recorded will be that for the Downloader(see table above).Logging Tamper EventsTamper events are normally logged. However please note that the type of events that areconsidered to be tampers depends to some extent on the options the Installer chooses inSystem Options – Jamming and System Options – Supervision (see page 100). Whenthese options are set to “Tamper” then jamming or supervision failure events will berecorded as tampers.Logging Software UpdatesThe control unit logs the software version every time the system starts up from zero power.To see the software version press or when the keypad displays the log message“System Startup”.AboutThe About option in the Installer Menu offers information on the version and status of thecontrol unit.If the control unit has a communications module fitted then the About option also providesinformation about the module, including IP addresses and port numbers for modulesconnected to the Internet.PanelThis option shows:The control unit modelThe control unit’s software revisionWhether the control unit is programmed as partition or part setting.The installed languages and their versions.Press or to see each item of information.Expanders30 50 160This option shows the first item in list of all the expanders known to the control unit. If youselect an expander by scrolling up or down the list and then press , the display showsthe revision of software running on the expander.KeypadsThis option shows the first item in a list of the keypads known to the control unit. If youselect a keypad by scrolling up or down the list and then press tick, the display shows therevision of software running on the keypad.Note: This option does not work for keypads whose internal software is earlier than V.012.If you find that the About option does not display an individual keypad’s software version,then you can check the keypad by briefly pressing the “A” and “” keys at the same time.