i-on Range Installer Menu OptionsPage 71Type:(nn=shortcut) Active when:Assign toPartitions?Pulsed?Smoke SensorReset (28)30 40 50160This output is active (0V) all the time except when auser acknowledges a fire alarm: after which thecontrol unit deactivates the output for three seconds.This output type is designed to be connected to low-voltage smoke detector reset terminals.Note: Some smoke detectors (for example theTexecom OH 4W) require that the user resetthe system twice after an alarm. This is to givethe detector time to close its alarm contactsafter the reset pulse.Yes No24 Hour Alarm(29)The control unit starts a 24 hour alarm. Yes YesSetting Complete(30)The control unit finishes setting. Active for 10seconds.Yes NoUnset Complete(31)Someone unsets the system or disarms it after analarm. The output is active for 10 seconds.Yes NoFull Set Ready(32)None of the detectors are reporting “alarm” signals.(Assigned to all partitions by default)Yes YesFull Set (33) The system is full set. If the system is partitioned,then the output is active only when all assignedpartitions are Full Set.Yes YesPart Set (34) The system is part set. Yes YesPart Set B (35) Setting Part Set B. Deactivated on unsetting PartSet B. (Available only in a Part Setting system)No YesPart Set C (36) Setting Part Set C. Deactivated on unsetting PartSet C. (Available only in a Part Setting system)No YesPart Set D (37) Setting Part Set D. Deactivated on unsetting PartSet D. (Available only in a Part Setting system)No YesSet Fail (38) A set command fails. Remains active until the useracknowledges the set fail.Yes YesZone Follow (39) A specified zone has been triggered. When youselect this type for an output the display shows extraoptions, see page 73. (You can also follow a “LogOnly” zone.)No YesZone Alarm (40) The selected zone causes an alarm. Deactivatedwhen the alarm has been reset. When you selectthis type for an output the display shows extraoptions, see page 74.No YesMasking (41)30 40 50160The control unit operates this output whenever adetector is giving a “mask” signal (see page 94).Yes Yes