i-on Range The Installer MenuPage 39MENU Option Factory Default NotesZone tampers Grade 2: YesGrade 3: NoFor INCERT approval set to NO.System tampers NoConfirmation (-EUR Version) EUR versions always use BasicConfirmation.Sounder on UnconfirmedSiren on UnconfirmedConfirmation (-UK Version)Confirmation ModeDD243 Not available for EUR versions.BS8243 Default for UK systems. Not available for EUR versions.BasicConfirmation time 30 minutes Visible for DD243 or BS8243.Can be adjusted between 1 and 60minutes. Note that only values of30 minutes or more comply withDD243 or BS8243.After Entry 1 zones Visible for DD243 or BS8243.Default changes to 2 zones whenConfirmation Mode = DD243.Entry Keypad Lock Off Visible for DD243 or BS8243.Sounder on Unconfirmed Visible for DD243, BS8243 andBasic.Siren on Unconfirmed Visible for DD243, BS8243 andBasic.Unconfirmed reset User Visible for DD243 or BS8243.Confirmed reset Installer Visible for DD243 or BS8243.HUA Confirm time 8 hours Visible for BS8243 only. Must bebetween 8 and 20 hours in order tocomply with BS8243:2010Tamper as Tamper-only EnabledProfiles 16 40Masking Grade 2: OffGrade 3: On 30 40 50 160 Masking“ON” is required in order to complywith EN50131-1, 8.2.1.Mask Override On 30 40 50 160 Appearsonly when Masking is On.Language English This option does not appear in UKversions.Restore DefaultsStaged defaults 30 50 160i-on30EX cannot change to 6-digituser codes.Factory defaultsCountry Defaults Appears on EUR systems only, aspart of Factory Default process.Installer Name “Installer” Required for web browser login.Installer Code Grade 2: “7890”Grade 3, “567890”i-on16, i-on30EX, and i-on40Grade 2 only.Keypad text Depends on control unit type.Remote needs Entry DisabledRemote Entry PrtSt DisabledRKP needs Entry DisabledRKP Entry PrtSt DisabledHUA Response Audible Appears here only in part settingsystem.Auto Rearm Never This setting is required in order to