Appendix II i-on RangePage 142P3 = YesSystem Options Wired Zone Type Select FSL if using all wired detectorsConfirmation Mode DD243 or BS8243ConfirmationTime30 minsAfter Entry 2 zonesEntry keypadLockOnSounder on UnconfirmedSiren on UnconfirmedUnconfirmedresetUserConfirmed Reset InstallerKeypad Text Enter Name of installer companySiren Delay (default 0 mins)Siren Time (default 15 mins)Force Set OffCSID Enter 4 digit ARC Scantronic reset code (ifrequired)Silence Alerts UserUser ProgrammingUser Code Type Partitions01 1234 Master User Whole system – P2 + P302 2222 Partition user P2 (Factory)03 3333 Partition user P3 ( Office)User OperationTo set:Full System User 01 enters code or Prox and selects a Partition.(User 01 can select an individual Partition or full set thewhole system.)Factory only(Partition 2)Partition 2 User enter Code or Prox in Keypad 2Office only(Partition 3)Partition 3 User enter Code or Prox in Keypad 1To Unset:First user to enter keys in their code or presents a ProxtagIf User 02 (a member of the Factory department) sets their Factory partition and the Officepartition is already set, then the common foyer area will also start to set. When the usercloses the Front Door (zone 1) the whole system sets and the alarm response is raised toFull alarm (Siren + Comms).The same thing will happen if User 03 sets the Office partition when the Factory partition isalready set.