The Installer Menu i-on RangePage 38MENU Option Factory Default Notessystems. Applies to both full andpart set partition.Siren Delay 0 minutes For full set only.Siren Time 15 minutes For full set only.To comply with EN50131-1 Clause8.6 minimum is 90s, maximum is15mins.Strobe on Set OffStrobe on Unset OffPart Set Exit Mode Instant SetPart Set Settle Time 15 seconds Appears only if Part Set Exit Modeis “Final Door” , “Lock Set” or “ExitTerminate”.Part Set Exit Time 40 seconds Appears only if Part Set Exit Modeis “Timed Set” or “Silent Set”.Part Set Entry Time 40 secondsPart Set AlarmResponseSiren Includes Internal alarm.This setting is required in order tocomply with EN50131.Part Set Siren Delay 0 minutes For part set.Part Set Siren Time 15 minutes For part set.To comply with EN50131-1 Clause8.6 minimum is 90s, maximum is15mins.Part Set Final Exit Final exitPart Set Entry Route Entry RoutePart Set Strobe Set OffPart Set Strobe Unset OffPartition 2...nn “Partition nn” Number of partitions depends onpanel type. All other defaults as forPartition 1.Full Set Link Partitions 2-nn: No 30 40 50 160. Number ofpartitions depends on panel type.Partition 1 is common partition.Calendar Set None 50 160No events or partitions4 SYSTEM OPTIONSWired Zone type Select the global wiring type duringinitial power up. Also affects i-on16when KEY-KPZ01 connected.Panel Zones 2 Wire FSL 2k2/4k7 30 40 50 160All Zones 2 Wire FSL 2k2/4k7 30 50 160This option also appears on i-on16and i-on40 when a wired keypadwith zones is fitted.User AccessHUA keys active NoQuick Set No This setting is required in order tocomply with EN50131.Quick Omit NoUser code req’d Yes This setting is required in order tocomply with EN50131.2 Way Replies Yes Used with FOB-2W-4B.2W Set Instant Yes Used with FOB-2W-4B.Duress Enable No (Change to Yes for Duress Code.)User resetZone alarms Yes This option appears only ifConfirmation Mode is ”Basic”