Installer Menu Options i-on RangePage 130Zones This option lets you select one or more individual zones, andtest only those zones and no others.Use or to scroll up and down the list of zones. Press or to display “Yes” at the end of the bottom line to mark thezone as one you want to test.When you select a Walk Test option (apart from the Chime option), the display shows thefirst item in a list of the detectors available for test. Walk around the area you wish to testand trigger each detector. If the Chime option is set to “Yes” then every time you trigger adetector the keypads and loudspeakers give confirmation tone. The bottom right of thedisplay shows an “A” if you trigger the Alarm input and a “T” if you trigger the Tamper.Note that if a zone has the Masking attribute enabled and the device is masked during thewalk test then the keypad display will also show a “T”.The top of the display shows the number of zones left to test. The control unit decreasesthe number of zones every time you trigger an individual Alarm input.The bottom line of the display shows the zone name. To see the zone number press or.Press to end the test.Note: Use the Walk Test option to test wired HUA switches. While you are using the WalkTest option activating a wired HUA switch will not cause a HUA alarm.If you wish to see which zones have not yet been tested then press the menu key. Thebottom line of the display will show the first in a list of those zones remaining to test. Asyou test each zone it will disappear from the display. Press the menu key again to return tothe full list of zones.Testing Roller Shutter Detectors160EX EURWhen testing roller shutter detectors pull out the string so that the sensor makes therequired number of clicks within 20s.Testing Shock SensorsWhen testing shock sensors create suitable sized impacts near the sensor.Adjusting Roller Shutter and Shock Sensor Sensitivity160EX EURIf you wish to change the sensitivity of roller shutter detectors then go toDetectors/Devices – Detectors – Program Zones, select the appropriate zone and adjustthe sensitivity figure. Remember to leave Installer Menu to save the new figure before re-testing the zone.Zone Resistances30 40 50 160Note: This menu item will also be available on the i-on16 when it is connected to a KEY-KPZ01.When you select Zone Resistance, the display shows the first of the available wireddetectors. Press or to see the other detectors in the list.The bottom line of the display shows the zone name. To see the zone number press or.