164 Configuring the DDI Mux moduleN0008589 3.3Configuring DDI Mux connectionsAfter you have installed the DDI Mux, configure the module settings in the Unified Manager.To configure the DDI Mux, you need to:• assign the DDI Mux modules under Resources, Media Bay Modules• assign the lines for voice traffic under Services, Telephony Services, Lines• assign lines to the Data Module portion of the module• configure the DDI Mux to work with the DTEBefore you start, record the settings for the DDI Mux in the form provided in the ProgrammingRecords. At the very least, you need the following configuration information:Assigning the DDI mux modules1 Click the keys beside Resources and Media Bay Modules.2 Click the DS30 Bus heading that was assigned to the DDI Mux.This Bus is the same as the DS30 bus you assigned to the DDI Mux using the DIP switches onthe module.3 Make sure the option in the Programmed Bus Type drop list is Trunk module.4 Click the heading of the next DS30 Bus.This Bus is the DS30 bus automatically assigned to the Data Module portion of the DDI Mux.5 Click the Programmed Bus Type drop list, then click Data module.Table 16 Configuring DDI Mux connectionsProtocol V.35 ❑ Loopback state: Off ❑ Manual DTE ❑Manual DS30 ❑ Automatic DTE ❑Fixed AccessLine ____ Channel ____ Line ____ Channel ____Line ____ Channel ____ Line ____ Channel ____Line ____ Channel ____ Line ____ Channel ____Line ____ Channel ____ Line ____ Channel ____Line ____ Channel ____ Line ____ Channel ____Line ____ Channel ____ Line ____ Channel ____Line ____ Channel ____ Line ____ Channel ____Line ____ Channel ____ Line ____ Channel ____Line ____ Channel ____ Line ____ Channel ____Line ____ Channel ____ Line ____ Channel ____Line ____ Channel ____ Line ____ Channel ____Line ____ Channel ____ Line ____ Channel ____