11.1 List of Parameters11.1.2 List of Parameters11-12PnBA22/STOP(Program TableOperation StopInput)Signal Allocation0000h to00C3h − 0020h Afterrestart Setup page 5-10PnBA32/JOGP(Forward JogInput)Signal Allocation0000h to00C3h − 0050h Afterrestart Setup page 5-11PnBA42/JOGN(Reverse JogInput)Signal Allocation0000h to00C3h − 0060h Afterrestart Setup page 5-11Continued on next page.Continued from previous page.ParameterNo. Size Name SettingRangeSettingUnitDefaultSettingWhenEnabledClassi-fication Referencen.X Signal Usage Method0 Stop program table operation when the /STOP signal turns ON (closes).1 Stop program table operation when the /STOP signal turns OFF (opens).2, 3 Program table operation is not stopped.n.X Signal Terminal NumberSame as PnBA0 = n.X.n.X Reserved parameter (Do not change.)n.X Reserved parameter (Do not change.)n.X Signal Usage Method0 Jog forward while the input signal is ON (closed).1 Jog forward while the input signal is OFF (open).2, 3 Forward jog operation is not performed.n.X Signal Terminal NumberSame as PnBA0 = n.X.n.X Reserved parameter (Do not change.)n.X Reserved parameter (Do not change.)n.X Signal Usage Method0 Jog in reverse while the input signal is ON (closed).1 Jog in reverse while the input signal is OFF (open).2, 3 Reverse jog operation is not performed.n.X Signal Terminal NumberSame as PnBA0 = n.X.n.X Reserved parameter (Do not change.)n.X Reserved parameter (Do not change.)