11.1 List of Parameters11.1.2 List of Parameters11-2311 Parameter ListPnBCD2/TGON(RotationDetection Output)Signal Allocation0000h to00C2h − 0002h Afterrestart Setup page 5-15PnBCE2/NEAR(Near Output) Sig-nal Allocation0000h to00C2h − 0002h Afterrestart Setup page 5-15PnBCF2/V-CMP(SpeedCoincidenceDetection Output)Signal Allocation0000h to00C2h − 0002h Afterrestart Setup page 5-16Continued on next page.Continued from previous page.ParameterNo. Size Name SettingRangeSettingUnitDefaultSettingWhenEnabledClassi-fication Referencen.X Signal Usage Method0 Turn ON (close) the output while the Servomotor is rotating.1 Turn OFF (open) the output while the Servomotor is rotating.2 Do not use this signal.n.X Signal Terminal NumberSame as PnBC0 = n.X.n.X Reserved parameter (Do not change.)n.X Reserved parameter (Do not change.)n.X Signal Usage Method0 Turn ON (close) the output when the position deviation is equal to or greater thanthe setting of PnB2F (Near Signal Width).1 Turn OFF (open) the output when the position deviation is equal to or greater thanthe setting of PnB2F (Near Signal Width).2 Do not use this signal.n.X Signal Terminal NumberSame as PnBC0 = n.X.n.X Reserved parameter (Do not change.)n.X Reserved parameter (Do not change.)n.X Signal Usage Method0 Turn ON (close) the output while the speed coincides.1 Turn OFF (open) the output while the speed coincides.2 Do not use this signal.n.X Signal Terminal NumberSame as PnBC0 = n.X.n.X Reserved parameter (Do not change.)n.X Reserved parameter (Do not change.)