SYSTEM UTILITIES9-3Edition OneXC1000 ServiceTable 9-1. Utility Menus andAccess Commands.Menu AccessCommandaInstall options ^DICopy options ^DCDrive tests ^DTDrive read-onlyb ^DOTerminal typeselection^DRa Press the Ctrl and D keys simultaneously,release the keys, then enter the secondcharacter.b Making a drive read-only can also be donefrom the Main Menu while XC1000 is inservice. Refer to section 9.6.2 for thisprocedure.The following messages pertain to problems that the IPL explicitly reports: TIMEOUT WAITING FOR CARD TO COME READY. The destinationcard did not respond to the IPL command. Control-bus messages arenot displayed. NO RESPONSE TO CB MESSAGE. Only a CB OUT message isdisplayed, because the CPU did not receive an input message. CHECKSUM ERROR ON RESPONSE PACKET. CB IN and CB OUTmessages are displayed with this message. UNRECOGNIZED ERROR. In the rare event that the IPL receives anunrecognizable response, this message is displayed. CB IN and CBOUT messages are also displayed.The IPL waits 10 minutes for the CB IN message before it times out. If theIPL was instructed to execute an operation and the SMT does not displayany activity within 10 minutes, the operation has failed. If the operationfailed, turn off the XC1000, turn it on again, and retry the operation.9.4 INSTALL OPTIONS: MENUTo access the INSTALL OPTIONS: menu, enter ^DI at the ENTER BOOTCOMMAND: prompt. Figure 9-2 shows the INSTALL OPTIONS: menu.The options on the menu are described in sections 9.4.1 through 9.4.13.9.4.1 Install-Option A – INSTALL DRIVEAny drive except system drive zero can be installed by using this option.Perform the following steps to use option A to install a drive:1. Run the initialize-drive utility (option D) before installing a new drive.New system or message drives that are added to the system must beinitialized before they are installed. Refer to section 9.4.4 for theinitialization procedure.SECTION 9.3 – 9.4