RELEASE 3.02 FCP CONVERSION INSTRUCTIONS14-13Edition OneXC1000 Servicec. At the > prompt, type reformat and press the Return key.Depending on the software release, either Figure 14-1 orFigure 14-2 appears again.5. Type 11 and press the Return key to select 11 – Check AMTaddresses vs. internal record numbers. Perform the following steps:a. At the ENTER “Y” TO CONFIRM AMT/UR CROSS CHECK:prompt, type Y and press the Return key.b. When CHECK DONE – PRESS ANY KEY TO CONTINUE appears,press the Return key. The > prompt reappears on the screen.c. At the > prompt, type reformat and press the Return key.Depending on the software release, either Figure 14-1 orFigure 14-2 appears again.6. Type 4 and press the Return key to select 4 – Garbage collect.Perform the following steps:a. At the ENTER “Y” TO CONFIRM GARBAGE COLLECTION:prompt, type Y and press the Return key to continue.b. At the ENTER DRIVE # TO GARBAGE COLLECT (0–15) OR ANYKEY FOR ALL DRIVES: prompt, press the Return key to rungarbage collect on all drives.c. At the ENTER “Y” TO CHANGE USER RECORDS AND UPDATEFREE SPACE TABLES, ENTER “N” TO LEAVE SYSTEMUNCHANGED: prompt, type Y and press the Return key tocontinue.d. When GARBAGE COLLECTION SUCCESSFUL...PRESS ANY KEYTO CONTINUE appears, press the Return key.e. Press ^C to return to the SMT Main Menu.Leave the XC1000 as is for the moment.14.7 LOAD MIRROR SOFTWARE, FCP CONVERSIONTOOL, AND SOFTWARE AND PHRASE DISKETTESPerform the steps in sections 14.7.1 through 14.7.3 to load software ontothe PC hard drive. If an FCP conversion was previously done using thesame PC, proceed directly to section 14.7.3.1. Make sure that the PC is plugged into an electrical wall outlet,2. Make sure that DOS 5.0 or higher is already installed on the PC harddrive. If DOS is not yet installed on the PC hard drive, install DOSbefore proceeding. For assistance, refer to the DOS software manual.3. If screen-saver software is installed on the PC, disable the softwarefor the FCP conversion by modifying c:\autoexec.bat on the PC. Forassistance, refer to the screen–saver software manual.If unable to disable the screen-saver software, when the screen blanksout during the procedure, press the Shift key to refresh the screen.SECTION 14.6 – 14.7