PLATFORM INSTALLATION3-28 Edition One XC1000 Service3.9.2 Busy-Out-Controller Cable ConnectionsIf the XC1000 has the busy-out-controller feature, it is located in the lower,back left corner of cabinet 1. The cable for the busy-out controller connectsto J1 on the rear of the busy-out controller, as shown in Figure 3-15.Refer to section 2.6 for information about the cable-pin assignments.REAR PANELJ1J2J3CONNECT TO 25-PAIRAMPHENOL CABLECONNECT TO OOS RELAYTO MONITOR CARDCONNECT TO J22 ONDISTRIBUTION BOARDFigure 3-15. Busy-Out-Controller Cable Connection.3.10 INSTALLING THE PRIMARY SMT AND OPTIONALPRINTERThe primary SMT shipped with the XC1000 is a Hewlett-Packard 700/43terminal. Other terminals can be used, including the Wyse 50, the DEC VT102or VT220, and the AT&T Teletype 4425 or 5425. This installation procedureapplies to the HP 700/43 only. For information about installing other terminals,refer to their specific manufacturer’s manuals. An optional printer can be usedwith the SMT to provide hard-copy records of system menus, statistics, distribu-tion lists, usage reports, and maintenance information.3.10.1 SMT InstallationThe SMT is usually located within 50 feet of the XC1000, which is required fora direct connection. Octel provides a 25-foot cable. If the SMT is more than 50feet from the XC1000, modems are required. Do not turn the terminal on untilthe system is fully installed. Use the following procedure to install the terminal:1. Place the SMT on a sturdy desk or table near the XC1000 so that itsconnecting cable to the XC1000 will not exceed 50 feet.2. Make sure that the ON/OFF power switch is set to OFF. The powerswitch is located at the lower left corner on the front of the terminal.SECTION 3.9 – 3.10