RELEASE 3.02 ONLINE UPGRADE INSTRUCTIONS15-6 Edition One XC1000 Service3. Plug the cable and adapter into the PC COM1 port.4. Leave the other end of the cable, P/N 057–1174–000, plugged into thedesignated SMT port, normally the J50 on the back of the XC1000.Figure 15-29 is a representation of the connection between the PC and theXC1000. The exact location of the PC COM port might vary among differentPCs.APC COM1 PORT IS USUALLY LOCATEDON THE BACK OR SIDE OF THE PCHARD DRIVE.BCJ43J44J45AXC1000 BACKJ46J47J48J49J50CABLE, PN 057–1174–000(ADAPTER INCLUSIVE)ADAPTER**P/N 003–1091–000(SMT PORT)COM1A = 25-PIN MALEB = 25-PIN FEMALEC = 9-PIN FEMALE** IF THE PC COM PORT HAS A 25-PIN MALE CONNECTION INSTEAD, USE A FEMLE/FEMALE DB25/DB25 GENDER CHANGERADAPTER, P/N 003–1092–000.Figure 15-29. Representation of PC–to–XC1000 Connection.15.8 INSTALL ONLINE UPGRADE TOOL 1.00 ON THE PCHARD DRIVEIf an online upgrade was previously done on the same PC, skip to section15.9.To install the online upgrade tool 1.00, perform the following steps:1. Make sure that DOS 5.0 or higher is already installed on the PC harddrive. If DOS is not installed on the PC, it must be installed before the1.00 upgrade can proceed. For assistance, refer to the DOS softwaremanual.2. If screen–saver software is installed on the PC, disable the software bymodifying c:\autoexec.bat on the PC. For assistance, refer to thescreen–saver software manual.3. If power management or battery conservation software is installed onthe PC, disable the software by modifying c:\autoexec.bat on the PC.For assistance, refer to the software manual.SECTION 15.7 – 15.8