RELEASE 2.X UPGRADE INSTRUCTIONS13-7Edition OneXC1000 ServiceENTER DRIVE # TO GARBAGE COLLECT (0–15) OR ANY KEY FOR ALL DRIVES:BEGIN GARBAGE COLLECT (ALL PORTS ARE CLEAR) . . .BEGIN FIRST PASS# SC ERRORS = 0# I/O ERRORS = 0# MESSAGES (DESTINATIONS) = 13# OF USERS WITH ERROR = 0# OF NODES WITH ERROR = 0ENTER “Y” TO CHANGE USER RECORDS AND UPDATE FREE SPACE TABLES,ENTER “N” TO LEAVE SYSTEM UNCHANGED:Figure 13-3. Garbage Collect, First Pass.13. Upon completion of the second pass, a screen similar to the one inFigure 13-4 appears. If SC or I/O errors are reported during thesecond pass, call the Octel Communications Technical AssistanceCenter.# SC ERRORS = 0# I/O ERRORS = 0# MESSAGES (DESTINATIONS) = 13# OF USERS WITH ERROR = 0# OF NODES WITH ERROR = 0PORT MSGS BLKS BOS TOT BOS ACT31 13 30 451310 409468TOTAL 13 30 451310 409468GARBAGE COLLECTION SUCCESSFULPRESS ANY KEY TO CONTINUEFigure 13-4. Garbage Collect, Second Pass.14. When the GARBAGE COLLECTION SUCCESSFUL prompt appears,turn off continuous-printing mode by pressing the Copy Pr key on theHP terminal or the Ctrl, Shift, and Print keys on the Wyse 50terminal.15. Press ^C twice to return to the Main Menu.13.6 BACK UP SYSTEM-DRIVE 0Perform the following steps to back up system-drive 0:1. Shut down the system using menu 13, option 1, suboption 2. If theXC1000 uses a T1 span that has no carrier, use suboption 1.2. When the ENTER BOOT COMMAND: prompt appears, turn theXC1000 power off at the main circuit breaker and allow the drives tospin all the way down.SECTION 13.5 – 13.6