Command Manual (For Soliton) – SNMP-RMONH3C S3100 Series Ethernet Switches Chapter 1 SNMP Configuration Commands1-1Chapter 1 SNMP Configuration CommandsNote:z The configuration of creating a MIB view with the mask of a MIB subtree is added.See section snmp-agent mib-view for details.z The configuration of encrypting a plain-text password is added. See sectionsnmp-agent calculate-password.z The configuration of adding “interface description” and “interface type” into alinkUp/linkDown trap is added. See section 1.1.21 snmp-agent trap ifmib.1.1 SNMP Configuration Commands1.1.1 display snmp-agentSyntaxdisplay snmp-agent { local-engineid | remote-engineid }ViewAny viewParameterslocal-engineid: Displays the local SNMP entity engine ID.remote-engineid: Displays all the remote SNMP entity engine IDs. At present, thedevice does not support application of the keyword.DescriptionUse the display snmp-agent command to display the local SNMP entity engine ID orall the remote SNMP entity engine IDs.Each device managed by the NMS needs a unique engine ID to identify an SNMPagent. By default, each device has a default engine ID. You should ensure that eachengine ID is unique within an SNMP domain.The creation of username and generation of cipher text password are related to engineID in SNMPv3. If you change an engine ID, the username and password configured onthe agent with this engine ID become invalid.