Command Manual (For Soliton) – System Maintenance and DebuggingH3C S3100 Series Ethernet SwitchesChapter 3 Device ManagementCommands3-10Examples# Display the alarm information of the transceiver on interface GigabitEthernet 1/1/2. display transceiver alarm interface gigabitethernet 1/1/2GigabitEthernet1/1/2 transceiver current alarm information:TX faultTable 3-6 Description on the fields of display transceiver alarm interfaceField Descriptiontransceiver current alarm information Current alarm information of thetransceiverTX fault TX fault3.1.10 display transceiver diagnosis interfaceSyntaxdisplay transceiver diagnosis interface [ interface-type interface-number ]ViewAny viewParametersinterface-type interface-number: Interface type and interface number.DescriptionUse the display transceiver diagnosis interface command to display the currentlymeasured value of digital diagnosis parameters of a single or all anti-spoofingtransceivers customized by H3C.Examples# Display the currently measured value of digital diagnosis parameters of theanti-spoofing pluggable optical transceiver customized by H3C on interfaceGigabitEthernet 1/2/2. display transceiver diagnosis interface gigabitethernet 1/2/2GigabitEthernet1/2/2 transceiver diagnostic information:Current diagnostic parameters:Temp(°C) Voltage(V) Bias(mA) RX power(dBM) TX power(dBM)35 3.26 6.18 -35.64 -5.17