Command Manual (For Soliton) – SNMP-RMONH3C S3100 Series Ethernet Switches Chapter 1 SNMP Configuration Commands1-12Field DescriptionStorage-typeStorage type, which can be:z volatile: Information will be lost if the system is rebootedz nonVolatile: Information will not be lost if the system isrebootedz permanent: Modification is permitted, but deletion isforbiddenz readOnly: Read only, that is, no modification, no deletionz other: Other storage typesUserStatus SNMP user status1.1.9 enable snmp trap updownSyntaxenable snmp trap updownundo enable snmp trap updownViewEthernet port view, interface viewParametersNoneDescriptionUse the enable snmp trap updown command to enable the sending of port/interfacelinkUp/linkDown traps.Use the undo enable snmp trap updown command to disable the sending oflinkUp/linkDown traps.By default, the sending of port/interface linkUp/linkDown traps is enabled.Note that you need to enable the generation of port/interface linkUp/linkDown trapsboth on the port/interface and globally if you want a port/interface to generateport/interface linkUp/linkDown traps when the state of the port/interface changes.To enable this function on a port/interface, use the enable snmp trap updowncommand; to enable this function globally, use the snmp-agent trap enable[ standard [ linkdown | linkup ] * ] command. By default, both are enabled.Examples# Enable the port Ethernet 1/0/1 to send linkUp/linkDown SNMP traps to the NMSwhose IP address is 10.1.1.1 using the community name public. system-view