Command Manual (For Soliton) – System Maintenance and DebuggingH3C S3100 Series Ethernet SwitchesChapter 3 Device ManagementCommands3-163.1.15 schedule reboot delaySyntaxschedule reboot delay { hh:mm | mm }undo schedule rebootViewUser viewParameterhh:mm: Reboot waiting delay, where hh ranges from 0 to 720, and mm ranges from 0 to59. The value of hh:mm can be up to 720:00.mm: Reboot waiting delay, ranging from 0 to 43,200 minutes.DescriptionUse the schedule reboot delay command to schedule a reboot on the switch, and setthe reboot waiting delay.Use the undo schedule reboot command to cancel the scheduled reboot.By default, no scheduled reboot is set on the switch.Note:The switch timer can be set to a precision of one minute, that is, the switch will rebootwithin one minute after the specified reboot date and time.You can set the reboot waiting delay in two formats: the hour:minute format and theabsolute minute format, and both must be less than or equal to 30 × 24 × 60 (that is, 30days).After you execute the command, the system will prompt you to confirm. Enter "Y" or "y"for your setting to take effect. Your setting will overwrite the previous one (if available).If you adjust the system time by the clock command after executing the schedulereboot delay command, the schedule reboot delay command will be invalid and thescheduled reboot will not happen.Related command: reboot, schedule reboot at, undo schedule reboot, displayschedule reboot.Example# Suppose the current time is 05:02, schedule a reboot so that the switch reboots after70 minutes.