190-02177-00 Rev. AGarmin G1000 NXi Pilot’s Guide for Cessna Nav IIISYSTEMOVERVIEWFLIGHTINSTRUMENTSEISAUDIO PANEL& CNSFLIGHTMANAGEMENTHAZARDAVOIDANCEAFCSADDITIONALFEATURESAPPENDICESINDEX38SYSTEM OVERVIEWSetting the generic timer:1) Use the FMS Knob to select the Aux - Utility Page.2) Press the FMS Knob momentarily to activate the flashing cursor.3) Turn the small FMS Knob to select the timer counting direction (Up/Dn) and press the ENT Key.4) If a desired starting time is desired:a) Use the large FMS Knob to highlight the HH:MM:SS field.b) Use the FMS Knob to enter the desired time and press the ENT Key.5) Turn the large FMS Knob to highlight ‘Start?’ and press the ENT Key to start the timer. The field changes to‘Stop?’.6) To stop the timer, press the ENT Key with ‘Stop?’ highlighted. The field changes to ‘Reset?’.7) To reset the timer, press the ENT Key with ‘Reset?’ highlighted. The field changes back to ‘Start?’ and the digitsare reset.The flight timer can be set to count up from zero starting at system power-up or from the time that theaircraft lifts off; the timer can also be reset to zero at any time.Setting the flight timer starting criterion:1) Use the FMS Knob to select the Aux - Utility Page.2) Press the FMS Knob momentarily to activate the flashing cursor.3) Turn the large FMS Knob to highlight the field next to the flight timer.4) Turn the small FMS Knob to select the starting criterion (Pwr-On or In-Air) and press the ENT Key.Resetting the flight timer:1) Use the FMS Knob to select the Aux - Utility Page.2) Press the MENU Key.3) With ‘Reset Flight Timer’ highlighted, press the ENT Key.