Operation Manual – SNMP-RMONH3C S3100 Series Ethernet Switches Chapter 2 RMON Configuration2-5Table 2-2 Display RMONOperation Command DescriptionDisplay RMON statisticsdisplay rmon statistics[ interface-type interface-number | unitunit-number ]Display RMON historyinformationdisplay rmon history [ interface-typeinterface-number | unit unit-number ]Display RMON alarminformation display rmon alarm [ entry-number ]Display extended RMONalarm informationdisplay rmon prialarm[ prialarm-entry-number ]Display RMON events display rmon event [ event-entry ]Display RMON event logs display rmon eventlog [ event-entry ]Available inany view.2.4 RMON Configuration ExamplesI. Network requirementsz The switch to be tested is connected to a remote NMS through the Internet.Ensure that the SNMP agents are correctly configured before performing RMONconfiguration.z Create an entry in the extended alarm table to monitor the information of statisticson the Ethernet port, if the change rate of which exceeds the set threshold, thealarm events will be triggered.II. Network diagramFigure 2-1 Network diagram for RMON configurationIII. Configuration procedures# Add the statistics entry numbered 1 to take statistics on Ethernet 1/0/1. system-view[Sysname] interface Ethernet 1/0/1[Sysname-Ethernet1/0/1] rmon statistics 1[Sysname-Ethernet1/0/1] quit# Add the event entries numbered 1 and 2 to the event table, which will be triggered bythe following extended alarm.