Operation Manual – Information CenterH3C S3100 Series Ethernet Switches Chapter 1 Information Center1-10Operation Command DescriptionSet to display the UTC timezone in the output informationof the information centerinfo-center timestamputcRequiredBy default, no UTCtime zone isdisplayed in theoutput information1.2.4 Setting to Output System Information to the ConsoleI. Setting to output system information to the consoleTable 1-7 Set to output system information to the consoleOperation Command DescriptionEnter system view system-view —Enable the informationcenter info-center enable OptionalEnabled by default.Enable systeminformation output tothe consoleinfo-center consolechannel{ channel-number |channel-name }OptionalBy default, the switch usesinformation channel 0 tooutput log/debugging/trapinformation to the console.Configure the outputrules of systeminformationinfo-center source{ modu-name | default }channel{ channel-number |channel-name } [ { log |trap | debug } { levelseverity | state state } ]*OptionalRefer to Table 1-8 for thedefault output rules ofsystem information.Set the format of timestamp in the outputinformationinfo-center timestamp{ log | trap | debugging }{ boot | date | none }OptionalBy default, the time stampformat of the log and trapoutput information is date,and that of the debuggingoutput information is boot.Note:To view the debugging information of some modules on the switch, you need to set thetype of the output information to debug when configuring the system information outputrules, and use the debugging command to enable debugging for the correspondingmodules.