Operation Manual – HWPingH3C S3100 Series Ethernet Switches Chapter 1 HWPing Configuration1-5Test parameter DescriptionTrapz A HWPing test will generate a Trap messageno matter whether the test successes or not.You can use the Trap switch to enable ordisable the output of trap messages.z You can set the number of consecutive failedHWPing tests before Trap output. You canalso set the number of consecutive failedHWPing probes before Trap output.1.2 HWPing ConfigurationThe TCP/UDP/jitter tests need the cooperation of HWPing client and HWPing Server,Other types of tests need to configure HWPing client and corresponding differentservers.1.2.1 Configuration on a HWPing ServerYou can enable both the HWPing client and HWPing server functions on an H3C S3100Ethernet switch, that is, the switch can serve as a HWPing client and serversimultaneously.I. HWPing server configuration tasksTable 1-3 HWPing server configuration tasksItem Description Related sectionEnable the HWPingserver functionThe HWPing server function is neededonly for jitter, TCP, and UDP tests. 1.2.1 II.Configure a listeningservice on the HWPingserverYou can configure multiple TCP/UDPlistening services on one HWPingserver, with each listening servicecorresponding to a specific destinationIP address and port number.1.2.1 II.II. HWPing server configurationTable 1-4 describes the configuration on HWPing server, which is the same for HWPingtest types that need to configure HWPing server.