Operation Manual – Information CenterH3C S5600 Series Ethernet Switches Chapter 1 Information Center1-5Module name DescriptionVRRP Virtual router redundancy protocol moduleVTY Virtual type terminal moduleXM XModem moduledefault Default settings for all the modulesTo sum up, the major task of the information center is to output the three types ofinformation of the modules onto the ten channels in terms of the eight severity levelsand according to the user’s settings, and then redirect the system information from theten channels to the six output directions.1.1.2 System Information FormatThe format of system information varies with the output destinations.z If the output destination is console, monitor terminal, logbuffer, trapbuffer, orSNMP, the system information is in the following format:timestamp sysname module/level/digest: - unitid –contentNote:z The space, the forward slash /, and the colon are all required in the above format.z Before may have %, “#, or * followed with a space, indicating log,alarm, or debugging information respectively.Below is an example of the format of log information to be output to a monitor terminal:%Dec 6 10:44:55:283 2006 Sysname NTP/5/NTP_LOG:- 1 - NTP service enable(“-1-“ indicates that the unit number of the device is 1.)z If the output destination is loghost, the switch and the log host use the syslogprotocol. The system information is in the following format according to RFC 3164(The BSD Syslog Protocol):timestamp sysname %%nnmodule/level/digest: source content