Operation Manual – Information CenterH3C S5600 Series Ethernet Switches Chapter 1 Information Center1-17To do… Use the command… RemarksConfigure the output rulesof system informationinfo-center source{ modu-name | default }channel{ channel-number |channel-name } [ { log |trap | debug } { levelseverity | state state } ]*OptionalRefer to Table 1-4 for thedefault output rules ofsystem information.Set the format of timestamp in the outputinformationinfo-center timestamp{ log | trap | debugging }{ boot | date | none }OptionalBy default, the time stampformat of the output loginformation is date.1.2.9 Setting to Output System Information to the SNMP NMSFollow these steps to set to output system information to the SNMP NMS:To do… Use the command… RemarksEnter system view system-view —Enable the informationcenter info-center enable OptionalEnabled by default.Enable information outputto the SNMP NMSinfo-center snmpchannel{ channel-number |channel-name }OptionalBy default, the switchoutputs trap information toSNMP through channel 5.Configure the output rulesof system informationinfo-center source{ modu-name | default }channel{ channel-number |channel-name } [ { log |trap | debug } { levelseverity | state state } ]*OptionalRefer to Table 1-4 for thedefault output rules ofsystem information.Set the format of timestamp in the outputinformationinfo-center timestamp{ log | trap | debugging }{ boot | date | none }OptionalBy default, the time stampformat of the informationoutput to the SNMP NMSis date.Note:To send information to a remote SNMP NMS properly, related configurations arerequired on both the switch and the SNMP NMS.