Operation Manual – QoS-QoS ProfileH3C S5600 Series Ethernet Switches Chapter 1 QoS Configuration1-36# Configure VLAN mapping on GigabitEthernet 1/0/10 to replace VLAN tag 500 withVLAN tag 100 and replace VLAN tag 600 with VLAN tag 200.[SwitchA] interface GigabitEthernet 1/0/10[SwitchA-GigabitEthernet1/0/10] traffic-remark-vlanid inbound link-group4002 remark-vlan 100[SwitchA-GigabitEthernet1/0/10] traffic-remark-vlanid inbound link-group4003 remark-vlan 200[SwitchA-GigabitEthernet1/0/10] quitDefine the same VLAN mapping rules on Switch B. The detailed configurationprocedure is similar to that of Switch A and thus is omitted here.1.6.4 Configuring Traffic Mirroring and Redirecting Traffic to a PortI. Network requirementsA company uses a switch to interconnect all the departments. As shown in Figure 1-11,z The marketing department is connected to GigabitEthernet 1/0/1 of the switch.The IP address segment for the hosts of the marketing department is192.168.1.0/25, and the hosts access the Internet through the switch.z The R&D department is connected to GigabitEthernet 1/0/2 of the switch. The IPaddress segment for the hosts of the R&D department is 192.168.2.0/25, and thehosts access the Internet through the switch.z The data monitoring device is connected to GigabitEthernet 1/0/3 of the switch.Configure traffic redirecting and traffic mirroring to satisfy the following requirements:z From 8:00 to 18:00 in working days, mirror the HTTP traffic from the marketingdepartment to the Internet to the data monitoring device.z From 8:00 to 18:00 in working days, redirect the HTTP traffic from the R&Ddepartment to the Internet to the data monitoring device.On the data monitoring device, the network administrator can analyze the HTTP trafficfrom each department to the Internet.