ABB ACS880 Series manuals
ACS880 Series
Table of contents
- List of related manuals
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Introduction
- Target audience
- Contents of the manual
- Cybersecurity disclaimer
- Drive configuration
- Configuring ACS355 drives
- Starting ACS355 drives for PROFINET
- ACS355 Minimum required parameter settings for PROFINET
- ACS355 More parameters written from PLC to drive (optional)
- ACS380 Minimum required parameter settings PROFIBUS DS
- Starting ACS380 drives for PROFINET
- ACS380 More parameters read from drive to PLC (optional)
- Configuring ACS550 drives
- Starting ACS550 drives for PROFINET
- ACS550 More actual values or parameters to be read from drive to PLC (optional)
- Configuring ACS580 drives
- ACS580 Minimum required parameter settings for PROFIBUS DP
- Starting ACS580 drives for PROFINET
- ACS580 Minimum required parameter settings for PROFINET
- ACS580 More parameters read from drive to PLC (optional)
- ACS800 Minimum required parameter settings for PROFIBUS DP
- Starting ACS800 drives for PROFINET
- ACS800 Minimum required parameter settings for PROFINET
- ACS800 More parameters read from drive to PLC (optional)
- ACS850 Minimum required parameter settings for PROFIBUS DP
- ACS850 Minimum required parameter settings for PROFINET
- ACS850 More parameters read from drive to PLC
- ACS880 Minimum required parameter settings for PROFIBUS DP
- Starting ACS880 drives for PROFINET
- ACS880 Minimum required parameter settings for PROFINET
- ACS880 More parameters written from PLC to drive (optional)
- ACSM1 Minimum required parameter settings for PROFIBUS DP
- Starting ACSM1 drives for PROFINET
- ACSM1 Minimum required parameter settings for PROFINET
- ACSM1 More parameters read from drive to PLC (optional)
- SIMATIC Manager
- Setting PG/PC interface
- Hardware configuration
- Adding Rack and CPU to the hardware
- Installing GSD files for ABB drives
- Adding drives to PROFINET
- Downloading Hardware configuration
- PLC libraries for S7-300
- Symbol Editor
- FB500 ABB_DRIVE_CONTROL_FB
- Block variables and data types
- Setting the drive in standby mode
- Setting the drive in run mode
- Downloading a program and setting PLC in run mode
- VAT table
- FC501 ACS_DRIVE_PZD (optional)
- Block variable and data types for FC501
- Scalable variables and data types
- FC500 ACS_DRIVE_PARA (optional)
- TIA portal
- Configuring S7-300 PLC
- Installing GSD and GSDML file for S7-300 PLC
- Adding ABB drives to PROFINET
- Downloading configuration to PLC
- Copying ABB drive libraries to S7-300 project
- Adding PLC tags to S7-300
- Adding watch and force tables
- FC501 ACS_DRIVE_PZD
- FC500 ACS_DRIVE_PARA
- Error codes for FB500 and FC500
- Configuring S7-1200 and S7-1500 PLC
- Installing GSD file for S7-1200 PLC
- PLC libraries for S7-1200
- Downloading configuration to S7-1200 PLC
- Copying ABB drive libraries to S7-1200 project
- Adding PLC tags to S7-1200
- Block variables and data types for FB500
- FB501 ACS_DRIVE_PARA
- Block variables and data types for FB501
- FB502 ACS_DRIVE_PZD
- Block variables and data types for FB502
- Further information
- Contact us
ACS880 Series
Table of contents
- Table Of Contents
- Table Of Contents
- Introduction
- Fieldbus grounding
- Drives with embedded fieldbus
- Fieldbus modules for ABB drives
- ABB cable TK505
- AC500 COM1 – Master at the bus line end
- AC500‐eCo COM2 – Master at the bus line end
- Drive configuration
- Starting up ACS310 drives with embedded Modbus RTU
- Starting up ACS355 drives with FMBA‐01 Modbus RTU adapter
- Starting up ACS800 drives with RMBA‐01 Modbus RTU adapter
- Starting up ACS850, ACQ810 drives with embedded Modbus RTU
- Starting up ACS880 drives with FSCA‐01 Modbus RTU adapter
- Starting up ACSM1 drives with FSCA‐01 Modbus RTU adapter
- Install drives library
- Control Builder Plus for PLC and Drives
- IP configuration of CPU (for Ethernet connection between PC and PLC)
- CODESYS
- Library Manager
- PLC logic
- Download program to PLC
- Create boot project
- Test the program
- Read and write more data between PLC and drive (optional)
- Visualizations
- Add more drives (optional)
- Actualization rate
ACS880 Series
Table of contents
- Table Of Contents
- Table Of Contents
- Contents of this chapter
- Safety
- Terms and abbreviations
- Centrifuge drive start-up
- Centrifuge I/O control connections
- Decanter drive start-up
- Decanter I/O control connections
- Optical link for Decanter
- Decanter scroll fault supervision
- Operating mode
- How to start and stop the Centrifuge
- How to halt the Centrifuge
- Decanter Operation
- Decanter control modes
- Decanter process load compensation
- Direct torque compensation
- Decanter control chain diagram of Scroll drive
- Decanter examples
- Back drive, variant B
- Forward drive
- Decanter jogging
- Parameters listing
- Centrifuge Decanter control
- Centrifuge pattern
- Decanter control
- About this chapter
- Fault messages
- Product and service inquiries
ACS880 Series
Table of contents
- EFFECTIVE: 2018
- Table Of Contents
- Table Of Contents
- Contents of this chapter
- Safety
- Start-up procedure
- Default control connections of SPRS control program (ZCU)
- SPRS operation
- SPRS connection diagram
- Benefits of using SPRS system
- Connecting to a drive with an Assistant control panel for the first time
- Ethernet network connection
- Communication profile
- Programmable digital inputs
- Programmable relay outputs
- Data storage parameters
- Terms and abbreviations
- Parameter listing
- I/O extension module 1
- SPRS User values
- Speed and Feedback SEL
- SPRS Limits
- Changed firmware default values for SPRS application
- How to reset
- Fault messages
- Warning messages
- Product and service inquiries
ACS880 Series
Table of contents
- Table Of Contents
- Table Of Contents
- Contents of this chapter
- Contents of the manual
- Cybersecurity disclaimer
- Start-up procedure
- Basic configuration of the distributed I/O bus
- CIO-01 I/O module
- Layout drawing
- Connection diagram
- LEDs
- Summary of parameter groups
- Parameter listing
- I/O bus service
- I/O bus diagnostics
- I/O bus fan identification
- Fieldbus addresses
- Parameter groups 206...209
- Warning messages
- Product and service inquiries
ACS880 Series
Table of contents
- List of related manuals
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- What this chapter contains
- Contents of the manual
- Local control vs. external control
- External control
- Operating modes of the drive
- Speed control mode
- Drive configuration and programming
- Adaptive programming
- Application programming
- Control interfaces
- Programmable I/O extensions
- Fieldbus control
- Master/follower functionality
- External controller interface
- Control of a supply unit (LSU)
- Motor control
- Constant speeds/frequencies
- Speed controller autotune
- Oscillation damping
- Rush control
- Encoder support
- Jogging
- Scalar motor control
- Autophasing
- Flux braking
- DC magnetization
- Application control
- Motor potentiometer
- Mechanical brake control
- DC voltage control
- Voltage control and trip limits
- Brake chopper
- Safety and protections
- Motor thermal protection
- Thermal protection of motor cable
- Other programmable protection functions
- Automatic fault resets
- Diagnostics
- Energy saving calculators
- Miscellaneous
- User lock
- du/dt filter support
- Sine filter support
- Factory macro
- Default control connections for the Factory macro
- Hand/Auto macro
- Default control connections for the Hand/Auto macro
- PID control macro
- Default parameter settings for the PID control macro
- Default control connections for the PID control macro
- Sensor connection examples for the PID control macro
- Torque control macro
- Default control connections for the Torque control macro
- Sequential control macro
- Selection of constant speeds
- Default control connections for the Sequential control macro
- Fieldbus control macro
- Terms and abbreviations
- Summary of parameter groups
- Parameter listing
- Input references
- Warnings and faults
- Control and status words
- System info
- Standard DI, RO
- Standard DIO, FI, FO
- Standard AI
- Standard AO
- I/O extension module 1
- I/O extension module 2
- I/O extension module 3
- Operation mode
- Start/stop/direction
- Start/stop mode
- Speed reference selection
- Speed reference ramp
- Speed reference conditioning
- Speed control
- Torque reference chain
- Frequency reference chain
- Limits
- Fault functions
- Supervision
- Generic timer & counter
- Load analyzer
- User load curve
- Process PID set 1
- Process PID set 2
- Energy efficiency
- Monitoring/scaling settings
- Data storage
- Panel port communication
- Fieldbus adapter (FBA)
- FBA A settings
- FBA B settings
- Embedded fieldbus
- DDCS communication
- D2D and DDCS transmit data
- D2D and DDCS receive data
- Feedback selection
- Encoder module settings
- Encoder 1 configuration
- Encoder 2 configuration
- LSU control
- HW configuration
- System
- User motor parameters
- Motor data
- Safety
- Fieldbus addresses
- Parameter groups 1...9
- Parameter groups 10...99
- Pure events
- Other data loggers
- QR Code generation for mobile service application
- Warning messages
- Fault messages
- Connecting the fieldbus to the drive
- Setting up the embedded fieldbus interface
- Setting the drive control parameters
- Basics of the embedded fieldbus interface
- Control word and Status word
- Register addressing
- About the control profiles
- The ABB Drives profile
- Status Word
- State transition diagram
- References
- Actual values
- Modbus holding register addresses
- The Transparent profile
- Modbus function codes
- Exception codes
- Coils (0xxxx reference set)
- Discrete inputs (1xxxx reference set)
- Error code registers (holding registers 400090...400100)
- Basics of the fieldbus control interface
- Contents of the fieldbus Control word (ABB Drives profile)
- Contents of the fieldbus Status word (ABB Drives profile)
- The state diagram (ABB Drives profile)
- Setting up the drive for fieldbus control
- Parameter setting example: FPBA (PROFIBUS DP)
- Speed reference source selection I
- Speed reference source selection II
- Speed reference ramping and shaping
- Motor feedback configuration
- Load feedback and position counter configuration
- Speed error calculation
- Speed controller
- Torque reference source selection and modification
- Operating mode selection
- Reference selection for torque controller
- Torque limitation
- Torque controller
- Frequency reference selection
- Frequency reference modification
- Process PID setpoint and feedback source selection
- Process PID controller
- Master/Follower communication I (Master)
- Master/Follower communication II (Follower)
- Product and service inquiries
ACS880 Series
Table of contents
- List of related manuals in English
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- What this chapter contains
- Contents of the manual
- Local control vs. external control
- External control
- Operating modes of the drive
- Torque control mode
- Drive configuration and programming
- Control interfaces
- Programmable I/O extensions
- Motor control
- Constant speeds (frequencies)
- Encoder support
- Jogging
- Scalar motor control
- Autophasing
- Flux braking
- DC magnetization
- Application control
- Mechanical brake control
- DC voltage control
- Voltage control and trip limits
- Brake chopper
- Safety and protections
- Programmable protection functions
- Automatic fault resets
- Diagnostics
- Load analyzer
- Miscellaneous
- Factory macro
- Default control connections for the Factory macro
- Hand/Auto macro
- Default control connections for the Hand/Auto macro
- PID control macro
- Default parameter settings for the PID control macro
- Default control connections for the PID control macro
- Sensor connection examples
- Torque control macro
- Default control connections for the Torque control macro
- Sequential control macro
- Selection of constant speeds
- Default control connections for the Sequential control macro
- Fieldbus control macro
- Summary of parameter groups
- Parameter listing
- Input references
- Control and status words
- System info
- Standard DI, RO
- Standard DIO, FI, FO
- Standard AI
- Standard AO
- Operation mode
- Start/stop/direction
- Start/stop mode
- Speed reference selection
- Speed reference ramp
- Speed reference conditioning
- Speed control
- Torque reference chain
- Frequency reference chain
- Limits
- Fault functions
- Supervision
- Maintenance timer & counter
- Motor thermal protection
- Process PID set 1
- Process PID set 2
- Energy efficiency
- Monitoring/scaling settings
- Data storage
- Panel port communication
- FBA A settings
- Feedback selection
- Encoder module settings
- Encoder 1 configuration
- Encoder 2 configuration
- HW configuration
- System
- User motor parameters
- Motor data
- Fieldbus addresses
- Parameter groups 1...9
- Parameter groups 10...99
- Warning/fault history
- Warning messages
- Fault messages
- System overview
- Basics of the fieldbus control interface
- Control word and Status word
- References
- Actual values
- Contents of the fieldbus Control word
- Contents of the fieldbus Status word
- The state diagram
- Setting up the drive for fieldbus control
- Parameter setting example: FPBA (PROFIBUS DP)
- Speed reference source selection I
- Speed reference source selection II
- Speed reference ramping and shaping
- Motor feedback configuration
- Speed error calculation
- Speed controller
- Torque reference source selection and modification
- Reference selection for torque controller I
- Reference selection for torque controller II
- Torque limitation
- Frequency reference selection
- Frequency reference modification
- Process PID setpoint and feedback source selection
- Process PID controller
- Product and service inquiries
ACS880 Series
Table of contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- What this chapter contains
- Target audience
- Terms and abbreviations
- Cybersecurity disclaimer
- DC/DC converter hardware start-up
- Parameter settings in the DC/DC converter control program
- Parameter settings for power control mode
- Testing the operation in local control mode
- Final settings
- Modbus settings
- DDCS communication settings
- Testing the PLC operation
- Contents of this chapter
- Control locations for start/stop
- Operating modes of the converter
- Control interfaces
- Programmable I/O extensions
- Run enable, Start/stop and Start enable control
- Example diagrams
- phase DC/DC converter
- Energy storage voltage measurement and estimation
- Reference chains
- Power reference chain
- Safety and protections
- Control unit temperature
- Load analyzer
- Default I/O connection diagram (BCU)
- DDCS communication
- Data storage (DDCS controller) parameters
- Summary of parameter groups
- Parameter listing
- Actual values
- Input references
- Diagnostics
- Control and status words
- System info
- Standard DIO, FI, FO
- Standard AI
- Standard AO
- Extension I/O module 1
- Extension I/O module 2
- Extension I/O module 3
- Operation mode
- Start/stop mode
- DC voltage reference
- DC voltage controller
- Current controller
- Fault functions
- Generic timer & counter
- Monitoring settings
- Panel port communication
- FBA A settings
- FBA B settings
- DDCS transmit
- DDCS receive
- BAMU configuration
- HW configuration
- System
- Chopper control
- Parameter groups 101...107
- Parameter groups 110...197
- Warning/fault history
- Warning messages
- Fault messages
- System overview
- Basics of the fieldbus control interface
- Contents of the fieldbus Control word
- Contents of the fieldbus Status word
- The state diagram
- Setting up the DC/DC converter for fieldbus control
- DC voltage reference chain
- Energy storage voltage selection
- Current control
- Current limitation
- Product and service inquiries
ACS880 Series
Table of contents
- EFFECTIVE: 2018
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table of contents
- What this chapter contains
- General safety in installation, start-up and maintenance
- Electrical safety in installation, start-up and maintenance
- Additional instructions and notes
- Grounding
- Additional instructions for permanent magnet motor drives
- General safety in operation
- Purpose of the supplement
- Layout of option +P940 (IP20, UL Open Type)
- Layout of option +P944 (IP20, UL Open Type)
- Planning the layout of the cabinet
- Arranging the grounding inside the cabinet
- Planning the attaching of the cabinet
- Planning the cooling
- Minimum air inlet and outlet grating sizes
- Installing drives above one another
- Required free space
- Planning the use of cubicle heaters
- Examining the installation site
- Unpacking and examining the delivery (frames R1 to R2)
- Unpacking and examining the delivery (ACS880-11 and ACS880-31 frame R3)
- Unpacking and examining the delivery (ACS880-01 frames R3 to R5)
- Unpacking and examining the delivery (ACS880-01 frames R6 to R9)
- Unpacking and examining the delivery (ACS880-11 and ACS880-31 frames R6 to R9)
- Installing the drive
- Checking the insulation of the assembly
- Power cable connection procedure (IEC)
- Connecting the control cables – ACS880-01 frames R1 and R2
- Installing the drive module shelves and connecting the cables – ACS880-01 frame R3
- Connecting the control cables – ACS880-01 frame R3
- Connecting the control cables – ACS880-01 frames R4 and R5
- Connecting the control cables - ACS880-01 frames R6 to R9
- Degree of protection
- R1 (Option +P940, IP20, UL Open Type)
- R1 (Option +P944, IP20, UL Open Type)
- R2 (Option +P940, IP20, UL Open Type)
- R2 (Option +P944, IP20, UL Open Type)
- R3 (Option +P940, IP20, UL Open Type)
- R3 (Option +P944, IP20, UL Open Type)
- R4 (Option +P940, IP20, UL Open Type)
- R4 (Option +P944, IP20, UL Open Type)
- R5 (Option +P940, IP20, UL Open Type)
- R5 (Option +P944, IP20, UL Open Type)
- R6 (Option +P940, IP20, UL Open Type)
- R6 (Option +P944, IP20, UL Open Type)
- R7 (Option +P940, IP20, UL Open Type)
- R7 (Option +P944, IP20, UL Open Type)
- R8 (Option +P940, IP20, UL Open Type)
- R8 (Option +P944, IP20, UL Open Type)
- R9 (Option +P940, IP20, UL Open Type)
- R9 (Option +P944, IP20, UL Open Type)
- R3 – Option +P940 (IP20, UL Open Type)
- R6 – Option +P940 (IP20, UL Open Type)
- R8 – Option +P940 (IP20, UL Open Type)
ACS880 Series
Table of contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- What this chapter contains
- Contents of the manual
- Terms and abbreviations
- Local control vs. external control
- External control
- Operating modes of the drive
- Speed control mode
- Drive configuration and programming
- Adaptive programming
- Control interfaces
- Programmable relay outputs
- Fieldbus control
- Master/follower functionality
- External controller interface
- Control of a supply unit (LSU)
- Motor control
- Constant speeds/frequencies
- Speed controller autotune
- Oscillation damping
- Resonance frequency elimination
- Encoder support
- Jogging
- Scalar motor control
- Autophasing
- Flux braking
- DC magnetization
- Hexagonal motor flux pattern
- Application control
- Motor potentiometer
- Mechanical brake control
- DC voltage control
- Voltage control and trip limits
- Brake chopper
- DC voltage control mode
- Safety and protections
- Motor thermal protection
- Thermal protection of motor cable
- Automatic fault resets
- Other programmable protection functions
- Diagnostics
- Energy saving calculators
- Miscellaneous
- User lock
- Reduced run function
- du/dt filter support
- Router mode for BCU control unit
- Factory macro
- Default control connections for the Factory macro
- Hand/Auto macro
- Default control connections for the Hand/Auto macro
- PID control macro
- Default parameter settings for the PID control macro
- Default control connections for the PID control macro
- Sensor connection examples for the PID control macro
- Torque control macro
- Default control connections for the Torque control macro
- Sequential control macro
- Selection of constant speeds
- Default control connections for the Sequential control macro
- Fieldbus control macro
- Summary of parameter groups
- Parameter listing
- Input references
- Warnings and faults
- Control and status words
- System info
- Standard DI, RO
- Standard DIO, FI, FO
- Standard AI
- Standard AO
- I/O extension module 1
- I/O extension module 2
- I/O extension module 3
- Operation mode
- Start/stop/direction
- Start/stop mode
- Speed reference selection
- Speed reference ramp
- Speed reference conditioning
- Speed control
- Torque reference chain
- Frequency reference chain
- Voltage reference chain
- Limits
- Fault functions
- Supervision
- Generic timer & counter
- Load analyzer
- User load curve
- Process PID set 1
- Process PID set 2
- Energy efficiency
- Monitoring/scaling settings
- Data storage
- Panel port communication
- Fieldbus adapter (FBA)
- FBA A settings
- FBA B settings
- Embedded fieldbus
- DDCS communication
- D2D and DDCS transmit data
- D2D and DDCS receive data
- Feedback selection
- Encoder module settings
- Encoder 1 configuration
- Encoder 2 configuration
- LSU control
- HW configuration
- System
- User motor parameters
- Motor data
- Safety
- Parameter groups 1...9
- Parameter groups 10...99
- Pure events
- Other data loggers
- QR Code generation for mobile service application
- Warning messages
- Fault messages
- Auxiliary codes for line-side converter warnings
- Auxiliary codes for line-side converter faults
- Connecting the fieldbus to the drive
- Setting up the embedded fieldbus interface
- Setting the drive control parameters
- Basics of the embedded fieldbus interface
- Control word and Status word
- Register addressing
- About the control profiles
- The ABB Drives profile
- Status Word
- State transition diagram
- References
- Actual values
- Modbus holding register addresses
- The Transparent profile
- Modbus function codes
- Exception codes
- Coils (0xxxx reference set)
- Discrete inputs (1xxxx reference set)
- Error code registers (holding registers 400090...400100)
- Basics of the fieldbus control interface
- Contents of the fieldbus Control word (ABB Drives profile)
- Contents of the fieldbus Status word (ABB Drives profile)
- The state diagram (ABB Drives profile)
- Setting up the drive for fieldbus control
- Parameter setting example: FPBA (PROFIBUS DP)
- Speed reference source selection I
- Speed reference source selection II
- Speed reference ramping and shaping
- Motor feedback configuration
- Load feedback and position counter configuration
- Speed error calculation
- Speed controller
- Torque reference source selection and modification
- Operating mode selection
- Reference selection for torque controller
- Torque limitation
- Torque controller
- Frequency reference selection
- Frequency reference modification
- DC voltage reference selection
- DC voltage reference modification
- Process PID setpoint and feedback source selection
- Process PID controller
- Master/Follower communication I (Master)
- Master/Follower communication II (Follower)
ACS880 Series
Table of contents
- List of related manuals in English
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- What this chapter contains
- Licensing
- Contents of the manual
- Drive start-up
- Winder control program start-up
- Local control vs. external control
- External control
- Operating modes of the drive
- Speed control mode
- Winder overview
- Infeeder (main drive)
- Material properties
- Diameter calculation
- Tension control
- Tension torque trim
- Tension speed trim
- Dancer speed trim
- Taper function
- Winder stall function
- Automatic roll change
- Web loss
- Speed control torque limitation
- Drive configuration and programming
- Adaptive programming
- Application programming
- Control interfaces
- Programmable relay outputs
- Fieldbus control
- Master/follower functionality
- External controller interface
- Motor control
- Constant speeds/frequencies
- Speed controller autotune
- Oscillation damping
- Rush control
- Position counter
- Jogging
- Scalar motor control
- Autophasing
- Flux braking
- DC magnetization
- Hexagonal motor flux pattern
- Application control
- Motor potentiometer
- Mechanical brake control
- DC voltage control
- Voltage control and trip limits
- Brake chopper
- Emergency stop
- Motor thermal protection
- Thermal protection of motor cable
- User load curve
- Other programmable protection functions
- Automatic fault resets
- Diagnostics
- Energy saving calculators
- Miscellaneous
- User lock
- Data storage parameters
- Factory macro
- Default control connections for the Factory macro
- Hand/Auto macro
- Default control connections for the Hand/Auto macro
- PID control macro
- Default parameter settings for the PID control macro
- Default control connections for the PID control macro
- Sensor connection examples for the PID control macro
- Torque control macro
- Default control connections for the Torque control macro
- Sequential control macro
- Selection of constant speeds
- Default control connections for the Sequential control macro
- Fieldbus control macro
- Terms and abbreviations
- Summary of parameter groups
- Parameter listing
- Input references
- Warnings and faults
- Control and status words
- System info
- Winder actual signals
- Standard DI, RO
- Standard DIO, FI, FO
- Standard AI
- Standard AO
- I/O extension module 1
- I/O extension module 2
- I/O extension module 3
- Operation mode
- Start/stop/direction
- Start/stop mode
- Speed reference selection
- Speed reference ramp
- Speed reference conditioning
- Speed control
- Torque reference chain
- Frequency reference chain
- Limits
- Fault functions
- Supervision
- Generic timer & counter
- Load analyzer
- Process PID set 1
- Process PID set 2
- Energy efficiency
- Monitoring/scaling settings
- Data storage
- Panel port communication
- Fieldbus adapter (FBA)
- FBA A settings
- FBA B settings
- Embedded fieldbus
- DDCS communication
- D2D and DDCS transmit data
- D2D and DDCS receive data
- Application setup
- Winder speed settings
- Tension/Dancer control
- Winder PID controller
- Mechanical losses compensation
- Turreting assistance
- Winder safety
- Virtual Roll
- Feedback selection
- Encoder module settings
- Encoder 1 configuration
- Encoder 2 configuration
- HW configuration
- System
- User motor parameters
- Motor data
- Safety
- Fieldbus addresses
- Parameter groups 1...9
- Parameter groups 10...99
- Pure events
- Other data loggers
- QR code generation for mobile service application
- Firmware warning messages
- Application warning messages
- Firmware fault messages
- Application fault messages
- Connecting the fieldbus to the drive
- Setting up the embedded fieldbus interface
- Setting the drive control parameters
- Basics of the embedded fieldbus interface
- Control word and Status word
- Register addressing
- About the control profiles
- The ABB Drives profile
- Status Word
- State transition diagram
- References
- Actual values
- Modbus holding register addresses
- The Transparent profile
- Modbus function codes
- Exception codes
- Coils (0xxxx reference set)
- Discrete inputs (1xxxx reference set)
- Error code registers (holding registers 400090...400100)
- Basics of the fieldbus control interface
- Contents of the fieldbus Control word (ABB Drives profile)
- Contents of the fieldbus Status word (ABB Drives profile)
- The state diagram (ABB Drives profile)
- Setting up the drive for fieldbus control
- Parameter setting example: FPBA (PROFIBUS DP)
- Drive control diagrams
- Speed reference source selection II
- Speed reference ramping and shaping
- Motor feedback configuration
- Load feedback and position counter configuration
- Speed error calculation
- Speed controller
- Torque reference source selection and modification
- Operating mode selection
- Reference selection for torque controller
- Torque limitation
- Torque controller
- Frequency reference selection
- Frequency reference modification
- Process PID setpoint and feedback source selection
- Process PID controller
- Master/Follower communication I (Master)
- Master/Follower communication II (Follower)
- Winder control diagrams
- Dancer control
- Friction compensation
- Inertia compensation
- Speed reference scaling
- Application PID controller
- Product and service inquiries
ACS880 Series
Table of contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Contents of this chapter
- Related manuals
- Selecting the main contactor (breaker)
- Selecting the supply transformer
- Additional notes
- A drive with a 12-pulse diode supply unit
- Examining the compatibility of the motor and drive
- Availability of du/dt filter and common mode filter by drive type
- Additional requirements for non-ABB high-output and IP23 motors
- Additional data for calculating the rise time and the peak line-to-line voltage
- Selecting the power cables
- Alternative power cable types
- Not allowed power cable types
- Additional US requirements
- Selecting the control cables
- Routing the cables
- Separate control cable ducts
- Implementing thermal overload and short circuit protections
- Multidrive modules
- Implementing a motor temperature sensor connection
- Implementing a ground fault protecting function
- Implementing the Emergency stop function
- Implementing the Prevention of unexpected start-up function
- Implementing the Power-loss ride-through
- Implementing a bypass connection
- Applicable standards
- Markings
- EMC compliance (IEC/EN 61800-3:2004 + A2012)
- Category C3
- EU Declaration of Conformity (Machinery Directive)
- UL and CSA checklist
- Disclaimers
ACS880 Series
Table of contents
- Table Of Contents
- Contents of this chapter
- Checking the delivery
- Moving and unpacking the drive
- Lifting the crate with a crane
- Moving the crate with a forklift
- Moving the unpacked drive cabinet
- Moving the cabinet on rollers
- Final placement of the cabinet
- Fastening the cabinet to the floor and wall or roof
- Fastening the cabinet (non-marine units)
- Alternative 2 – Using the holes inside the cabinet
- Fastening the cabinet (marine units)
- Joining cabinet sections together
- Miscellaneous
ACS880 Series
Table of contents
- Table Of Contents
- Table Of Contents
- Contents of this chapter
- Electrical safety precautions
- Target audience
- Terms and abbreviations
- Summary of wirings and settings
- Operation principle diagram
- Fault reaction function
- STO function in the inverter units
- Parameters for the STO function
- Parameters for the SSE function
- Inverter unit parameter settings
- Acceptance test reports
- Competence
- Relevant failure modes
- Compliance with the European Machinery Directive
Related products
ACS850 seriesACS580 SeriesACS380 SeriesACS-AP SeriesACSM1 SeriesACH580 SeriesAC-AP SeriesCP620 SeriesCP630 SeriesCP635 SeriesABB categories
Industrial Equipment
DC Drives
Controller
Relays
Measuring Instruments
Circuit breakers
Battery Charger
Industrial Electrical
Transformer
Switch
manualsdatabase
Your AI-powered manual search engine