1600 Sflow CommandsDefault ConfigurationThere are no pollers configured by default.The default poll interval is 0.Command ModeGlobal Configuration mode.User GuidelinesThe sflow instance must be configured using the sflow destination ownercommand before this command can successfully execute.Exampleconsole(config)#sflow 1 polling gigabitethernet 1/0/1-10 200sflow polling (Interface Mode)Use the sflow polling command in Interface Mode to enable a new sflowpoller instance for this interface if rcvr_idx is valid. An sflow poller sendscounter samples to the receiver. Use the no form of this command to resetpoller parameters to the defaults.Syntaxsflowrcvr-index pollingpoll-intervalno sflowrcvr-index polling•rcvr-index — The sFlow Receiver associated with the poller (Range: 1 - 8).•poll-interval — The sFlow instance polling interval. A poll interval of 0disables counter sampling. A value of n means once in n seconds a countersample is generated. (Range: 0 - 86400).Default ConfigurationThere are no pollers configured by default.The default poll interval is 0.