Operation Manual – GVRPH3C S7500 Series Ethernet Switches Chapter 1 GVRP Configuration1-6Table 1-2 Relations between the timersTimer Lower threshold Upper thresholdHold 10 centisecondsThis upper threshold is less thanor equal to one-half of the timeouttime of the Join timer. You canchange the threshold by changingthe timeout time of the Join timer.JoinThis lower threshold is greaterthan or equal to twice the timeouttime of the Hold timer. You canchange the threshold by changingthe timeout time of the Hold timer.This upper threshold is less thanone-half of the timeout time of theLeave timer. You can change thethreshold by changing the timeouttime of the Leave timer.LeaveThis lower threshold is greaterthan twice the timeout time of theJoin timer. You can change thethreshold by changing the timeouttime of the Join timer.This upper threshold is less thanthe timeout time of the LeaveAlltimer. You can change thethreshold by changing the timeouttime of the LeaveAll timer.LeaveAllThis lower threshold is greaterthan the timeout time of the Leavetimer. You can change thresholdby changing the timeout time ofthe Leave timer.32,765 centisecondsNote:The recommended settings of GARP timers:z GARP Hold timer: 100 centiseconds (1 second).z GARP Join timer: 600 centiseconds (6 seconds).z GARP Leave timer: 3000 centiseconds (30 seconds).z GARP LeaveAll timer: 12000 centiseconds (2 minutes).1.3 Displaying and Maintaining GVRPTo do… Use the command… RemarksDisplay GARP statistics display garp statistics [ interfaceinterface-list ]Display the settings of theGARP timersdisplay garp timer [ interfaceinterface-list ]Display GVRP statistics display gvrp statistics [ interfaceinterface-list ]Display the global GVRPstatus display gvrp statusAvailable inany view.