Operation Manual – Information CenterH3C S7500 Series Ethernet Switches Chapter 1 Information Center1-5the information with a severity level greater than the defined threshold will not be output.Therefore, when the severity threshold is set to “debugging”, all information will beoutput. Refer to Table 1-2 for description of severity and corresponding levels.Table 1-2 Severity definitions on the information centerSeverity Value Descriptionemergencies 1 The system is unavailable.alerts 2 Errors that need to be corrected immediatelycritical 3 Critical errorserrors 4 Common errorswarnings 5 Warningsnotifications 6 Normal information that needs to be noticedinformational 7 Normal prompt informationdebugging 8 Debugging informationNote that a slash (/) separates the level and digest.6) DigestIt is a phrase of 1 to 32 characters, summarizing the information.A colon (:) separates the digest and content.7) Information textInformation text contains the detail of system information.Note:The above section describes the formats of log information sent to a log host by aswitch. Some log host software will resolve the received information and modify itsformat, so that you may see that the log format displayed on the log host is differentfrom the one described in this manual.1.2 Information Center ConfigurationThe switch supports information output to six directions, and the system assigns oneinformation channel for each output direction by default, as shown in Table 1-3.